Operator's guide
Warning.
In case this appliance contains hydrocarbon refrigerant please refer to guidelines
listed below. As the appliance contains a flammable refrigerant, it is essential to
ensure that the refrigerant pipes are not damaged. Standard EN378 specifies that
the room in which you install your appliance must have a volume of 1m³ per 8 g of
hydrocarbon refrigerant used in the appliances. This is to avoid the formation of
flammable gas/ air mixtures in the room where the appliance is located in the event
of a leak in the refrigerant circuit. The quantity of the refrigerant used in your
appliance is indicated on the rating plate.
Keep ventilation openings in the appliance's cabinet or in the built-inWARNING:
structure clear of obstruction
Do not use other mechanical devices or other means to accelerate theWARNING:
defrosting process than those recommended by the manufacturer
Do not damage the refrigerant systemWARNING:
Do not use electrical appliances inside the refrigerated storage compartment,WARNING:
unless they are of a type recommended by the manufacturer
Do not expose the appliance to rainWARNING:
This appliance is not intended for use by young children or infirm personsWARNING:
unless they have been adequately supervised by a responsible person to ensure that
they can use the appliance safely. Young children should be supervised to ensure that
they do not play with the appliance
Always keep the keys in a separate place and out of reach of children●●
Before servicing or cleaning the appliance, unplug the appliance from the mains or●●
disconnect the electrical power supply
If the supply cord is damaged, it must be replaced by the manufacturer, its service●●
agent, or similarly qualified persons in order to avoid a hazard
Relevant for Australia: Supply cord fitted with a plug complies with AS/NZS 3112.●●
Frost formation on the interior evaporator wall and upper parts is a natural phenomenon.●●
Therefore, the appliance should be defrosted during normal cleaning or maintenance
Directions for replacing the illuminating lamps are to be included in the instruction●●
Please note that changes to the appliance construction will cancel all warranty and●●
product liability
WINE COOLER - VKG: This appliance is intended to be used exclusively●●
for the storage of wine
Before starting the appliance
Check that the cabinet is undamaged. Please report any damage immediately to
your dealer. Wash the cabinet and inner lining with a mild unscented detergent and
wipe it dry. Do not use abrasive scouring powder, steel wool or similar.
Maintenance
Switch off the appliance and pull out the plug when cleaning the cabinet.
Only use an unscented detergent when cleaning the cabinet inside.
You may remove the top panel and wash it when cleaning the cabinet inside.
The kick panel can be removed to faciliate a vacuum-cleaning of the floor.
To make the cooling system work at its optimum it is necessary from time to time to
clean the wire condensator and the compressor at the back of the cabinet by means
of a brush or a vacuum cleaner. Remember to clean the drain.
Installation.
See drawings
Install the cabinet in a dry place and so that it is not exposed to direct sunlight or
any other source of heat.