4.3
Mounting the
Unit
Consider
the
following
points
before
selecting
where to
install:
X Do not mount
the inverter
on flammable
conskuction
x
X
N
x
Installthe
unit by screwing
two screws.
.
1,2 Uselhe
M6'80mm expansion
bolts.
.3UseM4orM5.
x
x
materials.
Mount on
a solid surface
Install
this inverter
at eye
level in order
to allow
the
LCD display
to be
readatalltimes
For
proper
air circulation
to dissipate
heat,
allow a
clearance
ofaDprox.20
cm tothe
sideand approx.
50 cm
above and
below the
unit.
The ambient
tgmperature
should
be between
and
to ensure
optimal
operation.
The recommended
installation
position
is
to be
adhered
to lhe
wall vertically.
Be sure
to keep olher
objects
and surfaces
as shown
in the
diagaam to
guarantee sufficient
heat dissipalion
and to
have enough space
for
removing wires.
SUITABLE
FOR MOUNTING
ON
CONCRETE
OR OTHER
NON-COMAUSTIBLE
SURFACE
ONLY.