15
English
To unmount indoor unit
Press the 2 LL marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor unit and
unmount. (Fig. 42)
3-9. Drain Hose
a) The drain hose should be slanted downward to
the outdoors. (Fig. 43)
b) Never form a trap in the course of the hose.
c) If the drain hose will run in the room, insulate the
hose with insulation* so that chilled condensation
will not damage furniture or floors. (Fig. 44)
* Foamed polyethylene or its equivalent is recom-
mended.
Do not supply power to the
unit or operate it until all
tubing and wiring to the
outside unit are completed.
Condensation
Insulation material
(Locally purchased)
must be used.
Push
Fig. 43
4. Multiple Switch on the Remote Control Unit
Indoor Unit Types
(MCAF188R5I, MCAF248R5I)
S/M (Single/Multiple switch)
G Initially, the S/M switch is set to S (Single).
G Set this switch to M (Multiple) for multiple operation.
G Always press ACL button by a thin object such as the tip of a
pen after setting the S/M switch.
G Slide the cover in the direction indicated
by the arrow and remove it.
G Use a thin object such as the tip of a
pen to press the ACL button.
07-341 GRF318MR5I ENG 11/7/07 5:25 PM Page 15