A) HOW TO SET THE OFF TIME
1. Press the ON/OFF button to start
the
air conditioner.
2. Press the TIMER button till the OFF
sign blinks.
3. Press the + or - (HOUR) button until
the desired value is displayed.
4. Press the SET button to activate the
timer.
B) HOW TO SET THE ON TIME
1. Press the ON/OFF button to stop
the air conditioner.
2. Press the TIMER button till the ON sign blinks.
3. Press the + or - (HOUR) button until the desired value
is displayed.
4. Press the SET button to activate the timer.
C) HOW TO SET A PROGRAM FOR DAILY ON/OFF
OPERATION (OR VICEVERSA)
1. Press the TIMER button till the ON sign blinks.
2. Press the + or - (HOUR) button until the desired value
is displayed.
3. Press the TIMER button again, the OFF sign blinks.
4. Press the + or - (HOUR) button until the desired value
is displayed.
5. Press the TIMER button, then the SET button to activate
the timer.
D) HOW TO CLEAR THE TIMER
Press the CLEAR button if you want that every timer
operation will be cleared.
The mentioned data make reference to the conditioner
operating when the sensor on the remote control unit is
ON. (Refer to temperature sensor selector). If the sensor
on the indoor unit is being used then actual operation will
slightly differ from that described in the table.
High speed Med. speed Low speed
MANUAL
If you want to manually adjust speed just set the FAN SPEED
selector as desired.
NOTE
SETTING THE TIMER
3
1
4
2
SLEEP MODE
The SLEEP mode enables you to save energy.
1. Set the MODE selector to cool, dry or heat.
2. Press the SLEEP button.
3. The mark appears on the display. Press the
SLEEP button again to release the SLEEP function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or heat the room
to the set temperature, and then the thermostat will make
the unit pause. After about 1 hour, the air conditioner will
automatically reset the set temperature as follows (also
refer to graphs).
When the room temperature reaches the new set value,
the thermostat will cause the unit to pause. After about 1
hour the temperature will be raised by 1 °C in cooling, or
lowered by 1 °C in heating. This enables you to save energy
without sacrificing your comfort.
7
NOTE
If the procedure to set the timer is not completed, by pushing
the SET button, within 15 seconds the timer operation will
be cancelled and the last set-up is restored.
OPERATING MODE SET TEMPERATURE CHANGE
Heating Lowered by 1 °C
Cooling and Dehumidifying Raised by 1 °C
1°C
1°C
1 hour
1 hour TIME
Setting temperature
Room temperature
COOLING AND DEHUMIDIFYING
1°C
1°C
1 hour
1 hour TIME
Setting temperature Room temperature
HEATING