DEHUMIDIFYING (DRY)
COOL / DRY / HEAT Model Only
AUTOMATIC OPERATION
HEATING
COOL / DRY / HEAT Model Only
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat from outside
air. The heating efficiency will fall off when the outdoor temperature
is very low. If enough heat is not obtained with this air conditioner, use
another heating appliance in conjunction with it.
CAUTION
For several minutes after the start of heating operation, the indoor
fan will stay on off until the indoor heat exchanger coil has warmed
up sufficiently. This is because the COLD DRAFT PREVENTION
SYSTEM is operating. During this period, the STANDBY lamp remains
lit.
DEFROSTING OF HEAT EXCHANGER
OUTDOOR UNIT “STANDBY”
HOW TO SET THE PRESENT TIME
1. Press the PROGRAM button three times.
The time indication alone flashes.
2. Press the HH button until the
present time hour is displayed.
Press the MM button until the
present time minutes are
displayed.
The display will automatically
stop flashing except for the
« : » symbol after 10 sec.
ON I /OFF
BATTERIES
MODE
FLAP
FAN SPEED
SELECT
HH
MM
TIME SET
SETBACK
NIGHT
ACL
OFF E ON
CLOCK
TIMER
SELECT
A/C
SENSOR
1
2
3
COOLING
Verify that the main switch is in ON position and
that the mode selector of the indoor unit is in ON
position.
1. Set the MODE selector to COOL .
2. Press the ON/OFF button and switch the air
condioner ON.
3. Press the TEMP. buttons to set the desired
temperature (the temperature range is between
30 °C max. and 16 °C min.).
NOTE
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
4. Press the FAN SPEED selector button to the setting you want.
1.Set the MODE selector to HEAT .
2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
4.Press FAN SPEED selector button to the setting you want.
THE DISPLAY SHOWS THE SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
1
4
3
2
1.Set the MODE selector to AUTO .
2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
1.Set the MODE selector switch to “DRY” .
2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
When this setting is selected, the air conditioner calculates the
difference between the thermostat setting and the room temperature
and automatically switches to the COOL or HEAT mode as appropriate.
4.Press the FAN SPEED selector button to the setting you want.
THE DISPLAY SHOWS THE SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
NOTE
Use DRY operation when you want to reduce the humidity in the
room.
Once the room temperature reaches the set level, the unit repeats
the cycle of turning on and off automatically.
During DRY operation, the fan speed is automatically set to low or
very low and the fan stops every 20 and 10 seconds.
Dry operation is not possible if the indoor temperature is 15 °C or
less.
OPERATION WITH THE REMOTE CONTROL UNIT
Example of operation diagram in the (Auto) mode with the set room
temperature at 23°C.
ONON ON
1 H 1 H
MIN. MAX.
A
B
C
C
B
A
27
26
25
24
23
22
21
20
19
NOTE
The air conditioner changes the operation mode (from cool to heat or vice
versa, if one of the following conditions occurs:
- ZONE A: changes if the difference between the room temperature and the
temperature set on the remote control unit is at least 3°C..
- ZONE B: changes if the difference between the room temperature and the
temperature set on the remote control unit is at least 1°C, one hour after
the compressor stop.
- ZONE C: never changes if the difference between the room temperature
and the temperature set on the remote control unit is no more than 1°C.
TEST OFF ON
STANDBY LAMP
When the outdoor temperature is low, frost or ice
may appear on the heat exchanger coil, reducing
the heating performance.When this happens, a
microcomputer defrosting system operates. At
the same time, the fan in the indoor unit stops
and the STANDBY lamp remains lit until
defrosting is completed. Heating operation
restarts after several minutes.(This interval will
vary slightly depending on the room and outdoor
temperature).
6
COOL / DRY / HEAT Model Only
EG