EasyManua.ls Logo

Technics SL-QL5 - Safety Precautions; Insulation Resistance Test

Technics SL-QL5
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
@
CONTENTS
;
Page
‘SAFETY
PRECAUTION......................00.00005.
2
RESISTORS
AND
CAPACITORS.....................
13
LOCATION
OF
CONTROLS
..........................
3
REPLACEMENT
PARTS
LIST........................
14
DISASSEMBLY
INSTRUCTION
.......................
4
EXPLODED
VIEWS
......00
0000.
e
ccc
ccce
ccs
e
ee
15
HOW
TO
SET
THE
TONEARM
DRIVE
ROPE
..........
7
CIRCUIT
BOARDS
AND
WIRING
HOW
TO
REPLACE
CHIPS
...........................
8
CONNECTION
DIAGRAM
.......................
18
MEASUREMENTS
AND
ADJUSTMENT................
8
SCHEMATIC
DIAGRAM
......................000005.
21
TROUBLE
SHOOTING
..............0...00..00.0
0000,
10
BLOCK
DIAGRAM
..............0
0000...
c
cc
eccee
cece
24
FUNCTION
OF
TERMINAL
(MN
1425
FPC)...........
13
PACKING
wiigcoc00
Sud
das
Wane
wks
nge
Rees
eee
ees
26
@
SAFETY
PRECAUTION
.
Before
servicing,
unplug
the
power
cord
to
prevent
an
electric
shock.
When
replacing
parts,
use
only
manufacturer's
recommended
components
for
safety.
.
Check
the
condition
of
the
power
cord.
Replace
if
wear
or
damage
is
evident.
.
After
servicing,
be
sure
to
restore
the
lead
dress,
insulation
barriers,
insulation
papers,
shields,
etc.
Before
returning
the
serviced
equipment
to
the
customer,
be
sure
to
make
the
following
insulation
resistance
test
to
prevent
the
customer
from
being
exposed
to
a
shock
hazard.
DARWNS
e
INSULATION
RESISTANCE
TEST
1.
Unplug
the
power
cord
and
short
the
two
prongs
of
the
plug
with
a
jumper
wire.
2.
Turn
on
the
power
switch.
3.
Measure
the
resistance
value
with
ohmmeter
between
the
jumpered
AC
plug
and
each
exposed
metal
cabinet
part,
such
as
screwheads
antenna,
control
shafts,
handle
brackets,
etc.
Equipment
with
antenna
terminals
should
read
between
3MQ
and
5.2MQ
to
all
exposed
parts.
(Fig.
A)
Equipment
without
antenna
terminals
should
read
approximately
infinity
to
all
exposed
parts.
(Fig.
B)
Note:
Some
exposed
parts
may
be
isolated
from
the
chassis
by
design.
These
will
read
infinity.
Antenna
terminal
Exposed
Exposed
metal
metal
part
part
Ohmmeter
Ohmmeter
(Fig.
A)
(Fig.
B)
Resistance
=
3MQ2—5.2MQ
Resistance
=
Approx
oo
4.
If
the
measurement
is
outside
the
specified
limits,
there
is
a
possibility
of
a
shock
hazard.
The
equipment
should
be
repaired
and
rechecked
before
it
is
returned
to
the
customer.

Related product manuals