Installation
33
Dimensions
Combustible Surfaces
This appliance shall be installed in accordance with
AS 5601-2004 - Gas Installations Figure 5.1: Required Clearances
around Domestic Cooking Appliances.
Any adjoining wall surface situated within 200mm from the edge of
any burner must be a suitable non-combustible material for a
height of 150mm for the entire length of the appliance. Any
combustible construction above the appliance must be at least
600mm above the top of the burner and no construction shall be
within 450mm above the top of the burner. Zero clearance is
permitted on the side and rear adjoining surfaces below the
maintop.
If the bench-top is situated within 200mm from the edge of any
burner, it should be 10mm or more below the hob as shown above.
Install Range Hoods and Exhaust Fans in accordance with the
manufacturer’s instructions, no closer than 600mm above the
maintop for Range Hoods and 750mm for Exhaust Fans.
THE APPLIANCE MUST NOT BE INSTALLED ON A BASE.
The Gas Inlet
Connection is male
½" BSP and is
located 55mm from
the right and 560mm
from the floor.