sensitiveness and may fail to give alarm when the machine over travels, which could lead
to mechanical crash and damage to the machine. The way to check is to press the switch
with hand and see if it gives off alarm. You can also check if the I/O port input signal
changes.
(2) Regularly check the electrical parts. Make sure the plug in devices, cables and cords are
well connected. Keep the cabinet door closed when in operation. Opening the cabinet
door will not help it cool down. Regularly check and clean the fans and filter nets to
ensure proper ventilation.
(3) You are encouraged to utilize the machine and do not let it stay idle for long, especially
in the first year. The more you use the machine, the more likely the machine will be in
good condition in the future. If the machine stays idle for too long, the electrical parts are
exposed to moisture, heat, etc., thus reducing the service life of the machine. Make sure
to power up the machine from time to time (at least once a month). Perform regular
check and maintenance. Run the machine for one hour each time and the heat
generated will help reduce the humidity. This will also help you to find problems with the
machine in advance.