6.3 Common Problems | Error Messages | Solutions
Error Message Problem Solution
001 EMERGENCY STOP ACTIVE E-stop pushed in. Release E-stop, and click E-stop
release on screen.
010 CAUTION! OVERTRAVEL LIMIT ACTIVE G-codelewillgobeyond
the table size if run.
Adjustworkingorigin.
RedoG-codeletocorrectsize.
011 AXES NOT REFERENCED Machine has not been
homed.
Press Home All on screen.
013 MPG ENABLED Handwheel is active. Click on Auto or Continuous to
deactivate handwheel
034 AXIS DRIVES FAULT One of the axis amps shut
down.
Cycle power on and off to reset
amp. Check cables going to
Amp.
041 SPINDLE INVERTER 1 FAULT Spindle had a fault and
shut down.
Cycle power on and off to restart
inverter.
042 AXIS ON OVERTRAVEL LIMIT The over travel limit
switch has been triggered.
Slowlyjogmachineawayfrom
end of gantry. Check limit
switches for debris.
Error Message Problem Solution.
NC030 Circle is not Congruent.
Dynamic mode not Congruent.
G-codelehasanincorrectarc Arcsmustbeabsolutei’sandj’s,or
created using R. select one of these
options in the CAM post processor.
NC101 Process 1
Positive over Travel
TheG-codeleistryingtorun
beyond the table size.
AdjustOrigin.RedoG-codeFile.
NC123
Bad Cycle Mode
Tried to press Cycle start to run
le.
Hold is active, press Hold to release,
select Auto, press Cycle Start.
Problem Solution
Machine freezes during tool
change, or when it tries to do
atoolchangeinaG-codele.
This error can occur if the pneumatic sensor on the dust shroud is faulty.
To check this:
• Press dust Shroud UP on the main screen.
• Look at the sensor on the piston; it should be red when the shroud is up.
• If not, move the sensor around the cylinder until the light comes on.
• If the light will not come on, it will need to be replaced.
Syntax Error when loading a
G-codele
ThereisanunrecognizedcommandintheG-codele.
UsethecorrectTechnopostintheCAMpackageandoutputtheleagain.