- Original instruction manual -
Instruction Manual
beta.d-line
8095AENA999
90000030766-02 - EN
2011-05-02
technotrans AG
Robert-Linnemann-Straße 17
D-48336 Sassenberg
Phone 02583 / 301-1000
Fax 02583 / 301-1030
http://www.technotrans.de

Table of Contents

Questions and Answers

  • A
    Amanda SmithAug 19, 2025
    How to troubleshoot technotrans manroland beta.d 120 L unit not working?
    • J
      Jonathan SpencerAug 20, 2025
      If your technotrans Industrial Equipment unit isn't working, start by checking the power supply is switched on. Then, check the external fuse protection, the supply cable for damage and proper connection, and the electrical circuit. Also, inspect any matching transformer or power supply unit for correct operation and configuration. Finally, check the fuses.
  • D
    dhenryAug 21, 2025
    What to do if technotrans manroland beta.d 120 L refrigeration unit is not running?
    • C
      christopherhoAug 21, 2025
      If your technotrans Industrial Equipment refrigeration unit is not running or has reduced capacity, reset the compressor circuit breaker. Check the flow, and clean the condenser (for air-cooled versions). Ensure sufficient cooling air (for air-cooled versions) and chilling medium supply (for water-/glycol-cooled versions). Press the reset button on the pressure switch. Check the refrigerant (look for bubbles in the sight glass). Clean condenser cooling fins, and allow the fan motor to cool off (approximately 30 minutes), replace if necessary. Remove any obstructions from the unit. Check for sufficient external suction and chilling medium supply. Clean the chilling medium supply filter.
  • J
    Jenna ChavezAug 23, 2025
    What to do if technotrans Industrial Equipment has insufficient dampening solution supply?
    • D
      David WellsAug 25, 2025
      If there is an insufficient dampening solution supply in your technotrans Industrial Equipment, reset the circuit breaker. Check and replace if necessary. Switch on the pumps at the control unit. Check the intermediate tank pump and the alcohol stabilizer.
  • K
    Kyle GreeneAug 26, 2025
    How to fix incorrect additive dosing in technotrans manroland beta.d 120 L?
    • S
      Steven MorganAug 26, 2025
      To fix incorrect additive dosing in your technotrans Industrial Equipment, top up the additive container if it's empty. Switch on the additive dosing if it's off. Adjust the dosing level via the dosing adjuster if the dampening solution doser adjustment is incorrect. Open the fresh water valve if it's closed. Ensure external fresh water pressure if it's insufficient. Clean the fresh water filter if there's insufficient fresh water throughput. Clean the suction tube foot filter if it's dirty. Remove the additive doser and blow out the fresh water input side with compressed air several times if the doser drive unit is not running.
  • M
    Melissa MyersAug 27, 2025
    Why is the dampening solution too warm in my technotrans manroland beta.d 120 L?
    • C
      Carl JohnsonAug 28, 2025
      If the dampening solution in your technotrans Industrial Equipment is too warm, adjust the temperature setpoint if it is too high. Reset the circuit breaker if the pump does not work, check and replace if necessary. Switch on the pumps and the dampening solution circuit at the control unit. Check the alcohol concentration in the dampening solution, as it may be too high.
  • B
    brandon12Aug 29, 2025
    What causes conductivity to be too high or low after dosing in technotrans manroland beta.d 120 L Industrial Equipment?
    • J
      Jeremy ClarkAug 29, 2025
      If the conductivity is too high or too low after dosing in your technotrans Industrial Equipment, check the conductivity of the fresh water supply. Verify that the tanks are not mixed up. Replace the dampening solution doser if it is defective. Clean the conductivity sensor if it is dirty.
  • T
    Theresa CruzAug 31, 2025
    What to do for pH value too high or too low in technotrans manroland beta.d 120 L?
    • D
      Debra ParkerSep 1, 2025
      If the pH value is too high or too low in your technotrans Industrial Equipment, clean the pH sensor if it's dirty. Replace the pH sensor if it's defective. Calibrate the system if it's not calibrated.
  • M
    Mary RobinsonSep 2, 2025
    What does it mean if all functions are inoperative on technotrans Industrial Equipment?
    • J
      Jonathan SchmidtSep 2, 2025
      If all functions are inoperative on your technotrans Industrial Equipment but the unit control system display is active, check the alcohol concentration and the temperature of the dampening solution (if the dampening solution temperature is over 40 °C, it can cause an IPA safety shut-off). Switch the unit OFF/ON at the maintenance switch, then check the fault message. If the cause of the fault is not eliminated, the unit switches itself off again after 15 minutes.
  • D
    david77Sep 4, 2025
    How to troubleshoot conductivity being too high or low in technotrans Industrial Equipment?
    • T
      Tina AbbottSep 5, 2025
      To troubleshoot conductivity being too high or low in your technotrans Industrial Equipment, clean the conductivity sensor if it is dirty or replace the conductivity probe if it is defective.
  • B
    Brandon KnightSep 6, 2025
    Why is the dampening solution too cold in my technotrans manroland beta.d 120 L Industrial Equipment?
    • B
      Brooke MaldonadoSep 7, 2025
      If the dampening solution in your technotrans Industrial Equipment is too cold, adjust the temperature setpoint if it's too low. Check the positioning of the temperature sensor if there's poor heat transmission. Check and replace the temperature sensor if it's defective.

Summary

Safety

General information regarding safety

Outlines fundamental safety principles and symbols used throughout the manual.

Safety of personnel

Details crucial safety measures and precautions for individuals operating or maintaining the unit.

Intended use

Specifies the correct applications and limitations for the unit's operation.

Installation site

Provides guidelines for selecting an appropriate and safe location for unit installation.

Safety instructions for transport

Details essential safety procedures and precautions to follow during the unit's transportation.

Use of chemicals

Outlines hazards and precautions when handling various chemicals, including flammable and aggressive substances.

Explosion protection

Provides essential information for operating the unit in potentially explosive environments.

Safety instructions for set-up

Essential safety guidelines to follow before and during the unit's initial setup.

Safety instructions for maintenance

Crucial safety procedures to observe when performing maintenance activities on the unit.

Setting Up

Installation

Guides on how to physically install the unit and connect it to the printing press.

Disconnecting the unit

Outlines the safe procedures for disconnecting the unit, including disassembly and recycling.

Operation

General information

Provides initial guidelines and checks before operating the unit.

Adjustments

Details the steps for adjusting system parameters and activating components during operation.

Notes concerning the software

Offers tips and checks for resolving software-related issues during unit operation.

Symbol description

Defines the meaning of various symbols and display colours used in the unit's interface.

Program overview

Presents a hierarchical overview of the unit's software functions and navigation paths.

Sensor adjustment

Details how to adjust and calibrate various sensors connected to the unit.

pH calibration

Provides instructions for calibrating the pH sensor to ensure accurate measurements.

Maintenance

Overview

Provides an overview of the maintenance schedule and the legend for maintenance symbols.

Maintenance plan

Provides general information and the structure of the maintenance schedule.

Dampening solution circuit (D-circuit)

Outlines the maintenance tasks and intervals for the dampening solution circuit.

Refrigeration circuit

Details the maintenance procedures and intervals for the unit's refrigeration circuit.

Refrigeration unit

Details maintenance for the condenser/heat exchanger of air-cooled refrigeration units.

Troubleshooting

Control unit

Guides on troubleshooting fault messages displayed on the control unit and using help texts.

Dampening solution circuit (D-circuit)

Lists common faults related to the dampening solution supply and their potential causes and solutions.

Refrigeration unit

Addresses troubleshooting steps for issues related to the refrigeration unit not running or having reduced capacity.

Technical Data

Connections

Details all external connection points, interfaces, and supply lines for the unit.

Electrical connection

Lists electrical specifications, fuse protection, and power consumption data for different unit versions.

Refrigerant circuit (R-circuit)

Details technical specifications for the refrigerant circuit, including refrigerant type and cooling capacities.

Proof of inherent safety in accordance with DIN EN 60079-14

Electrical data

Presents detailed electrical data for intrinsically safe equipment and associated apparatus, including parameters like Ui, Ii, Pi.

Configuration of the electrical parameters

Explains how electrical parameters are configured for safe interconnection according to EN 60079-14.

Manufacturers declaration

Contains the manufacturer's formal declaration regarding the safety and compliance of the unit.

Declaration of conformity

technotrans manroland beta.d 120 L Specifications

General IconGeneral
Brandtechnotrans
Modelmanroland beta.d 120 L
CategoryIndustrial Equipment
LanguageEnglish