Section 3 Emergency procedures
PITOT HEATING SYSTEM FAILURE
4
th
Edition, Rev. 0
2.5. PITOT HEATING SYSTEM FAILURE
When the Pitot Heating system is activated, the green PITOT HEAT advisory
light is turned ON.
If the amber PITOT HEAT caution light turns OFF, then the Pitot Heating sys-
tem is functioning properly. Anytime the amber PITOT HEAT caution light is
ON at the same time the green PITOT HEAT light is ON, then the Pitot Heating
system is not functioning properly.
1. Pitot heat switch
OFF
2. Verify Pitot Heating circuit breaker is IN
3. Pitot heat switch
ON
4. Check PITOT HEAT caution light:
If the amber light stays ON, assume a failure in the pitot heating system.
Avoid visible moisture and OATs below 10 deg C.