Page 3 - 17
Section 3 Emergency procedures
POWERPLANT EMERGENCIES
4
th
Edition, Rev. 0
4.5. LOW FUEL PRESSURE
If fuel pressure decreases below the lower limit (2.2 psi), apply following proce-
dure:
1. Fuel press CHECK
2. Fuel quantity CHECK
3. Fuel consumption MONITOR
If a fuel leakage is deemed likely
4. Land as soon as possible.
If a fuel leakage can be excluded:
4. Electrical fuel pump ON
5. Feed the affected engine by means of opposite side fuel tank
If pressure does not come back within the limits
6. Land as soon as practical