Section 3 – Emergency Procedure
SMOKE AND FIRE
ENGINE FIRE IN-FLIGHT
Cabin heating:
Fuel selector valve:
Electric fuel pump:
Throttle:
Magnetos:
Cabin vents:
OFF
OFF
OFF
FULL FORWARD until the engine stops
OFF
OPEN
7. Land as soon as possible applying forced landing procedure (See Para. 7).
Do not attempt engine restart
If smoke persists:
1.
Generator & Master switches: OFF
2.
Land as soon as possible and evacuate the aircraft
If the MASTER SWITCH is set to OFF, consider that flaps
extension and pitch trim operation would be not possible.
CABIN FIRE / ELECTRICAL SMOKE IN CABIN DURING FLIGHT
Cabin heating:
Cabin vents:
Door:
OFF
OPEN
OPEN, if necessary
Try to choke the fire. Direct the fire extinguisher (if on board) towards
flame base
ELECTRICAL SMOKE/FIRE IN CABIN ON THE GROUND
Generator Switch:
Throttle Lever:
Magnetos:
Fuel Selector Valve:
MASTER SWITCH:
Aircraft Evacuation
OFF
IDLE
OFF
OFF
OFF
carry out immediately