GSM-TE809-EN_rev2.doc Page 1/8
PREFACE
Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of
satisfaction. This manual is designed to put you in a position to intervene on the equipment and different performs of
installation and connection. In order to ensure efficient operation and durability, it is recommended the strict observance of
the rules laid down here. Thanks in advance for the suggestions that we will be given to possible further improvements of
the equipment. For any question always consult the TECNOELETTRA Technical Department.
TECNOELETTRA S.r.l.
Note:
The manufacturer reserves the right to modify equipment for any manufacturing or commercial need, without the
obligation to promptly update this installation and using manual.
This manual cannot be modified without authorization by TECNOELETTRA.
This material is the exclusive property of TECNOELETTRA, and cannot be used or disclosed for purposes other than those
contractual.
GSM modem
Instruction
s
Manual
Question and Answer IconNeed help?

Do you have a question about the tecnoelettra TE809 and is the answer not in the manual?

Summary

Preface

GSM Communication and Connection

Preliminary Connection Instructions

Instructions for initial setup and connection of the GSM system.

Serial Cable Connection

Connect the GSM modem via a 9-pole serial cable (male-female).

Antenna Connection

Connect the antenna to the GSM modem for optimal signal reception.

Power Connection

Connect the 8-32Vdc power supply cord to the GSM modem unit.

SIM Card Settings

Configure SIM card settings, including PIN disabling, for modem operation.

LED Diagnosis

Understanding LED indicators for GSM modem status and operation.

On-board Settings

Configure serial port parameters for GSM communication.

SMS Command and Control

Phone Number Settings

Configure mobile phone numbers for SMS alerts and commands.

SMS Commands Reference

Utilize SMS commands for system control, status monitoring, and operations.

Overview

The TECNOELETTRA GSM modem, as detailed in its instruction manual, is a crucial component designed to facilitate communication and control for a TE809 GSM system. This manual, GSM-TE809-EN_rev2.doc, provides comprehensive guidance for installation, connection, operation, and maintenance, emphasizing the importance of adhering to the outlined rules for efficient and durable performance. The manufacturer, TECNOELETTRA S.r.l., reserves the right to modify the equipment without prior notice, and the manual itself is proprietary material, not to be reproduced or disclosed without authorization.

Function Description

The GSM modem serves as a communication interface for the TE809 controller, enabling remote monitoring and control through SMS commands. Its primary function is to allow users to interact with the TE809 system, receive status updates, and issue operational commands via text messages from a mobile phone. This capability is particularly useful for managing generators or other connected equipment remotely, providing flexibility and convenience. The modem supports both manual and automatic modes of operation for the TE809, allowing for versatile control based on user needs. It can report various system parameters, including voltages, frequency, battery status, work hours, and fuel levels, making it a comprehensive remote diagnostic tool.

Important Technical Specifications

The manual highlights several key technical specifications and requirements for the GSM modem:

  • Power Supply: The modem operates on an 8-32Vdc power supply, indicating its compatibility with a range of DC power sources, likely battery-backed systems common in generator applications.
  • Serial Connection: It connects to the TE809 controller via a 9-pole serial cable (code 51C3), using male and female connectors for secure data transmission. The TE809's serial port needs to be configured for GSM communication, with specific parameters for RS232 (Parameter D: Gsm modem, Parameter E: 9600) or RS485 (Parameter B: Gsm modem, Parameter C: 9600) if a converter is used.
  • Antenna: The modem requires an external antenna with a magnetic base, designed to ensure good signal quality and allow for flexible placement on metal supports.
  • SIM Card: A standard SIM card is essential for the modem's operation. Crucially, the SIM card's PIN code request must be disabled before insertion into the modem to ensure proper functionality.
  • LED Diagnosis: An LED indicator provides visual feedback on the modem's status. A slow blink (every 1 second) indicates normal pre-operation, while a faster blink (every 2-3 seconds) signifies normal operation with the modem enabled. Persistent slow blinking suggests a problem, such as a missing SIM card, an enabled PIN, or poor GSM signal.

Usage Features

The GSM modem offers a range of usage features centered around SMS communication:

  • Phone Number Setting: Users can configure up to five mobile phone numbers to which the TE809 will send messages. This is done by sending an SMS command in the format SETx:+[phonenumber], where x is the position (1-5) and [phonenumber] is the full international number. The system confirms successful configuration with a reply SMS.
  • Number Replacement and Deletion: Existing phone numbers can be replaced by sending a new SETx command for the desired position. Numbers can be permanently deleted by sending an "empty number" command, such as SETx:.
  • SMS Commands for Control: A comprehensive list of SMS commands allows users to control various aspects of the TE809 system:
    • Man: Selects manual mode on the TE809.
    • Aut: Selects automatic mode on the TE809.
    • Test: Puts the TE809 into test mode.
    • Off: Selects Off mode on the TE809.
    • Reset: Resets alarms on the TE809.
    • Start: Starts the generator in manual mode.
    • Stop: Stops the generator in manual mode.
    • Info: Requests an SMS with important system information and measurements.
    • Kr: Closes the mains contactor.
    • Kg: Closes the generator contactor.
    • Lock: Addresses a "system block" alarm, allowing the engine to start again.
  • Combined Commands: Multiple commands can be sent in a single SMS, separated by semicolons (e.g., Man;Start;Info), allowing for complex sequences of operations and immediate feedback.
  • Information Retrieval (Info command): This command provides detailed status updates, including:
    • MODE: Current operating mode (Manual, Auto, Reset/Off).
    • VM: Mains voltages (for TE809A and TE809Ats models).
    • VG: Generator voltages.
    • FG: Generator frequency.
    • Vb: Battery voltage.
    • H: Work hours.
    • KG: Generator contactor status (open/closed, for TE809A and TE809Ats).
    • En: Motor state (stopped/started).
    • KR: Mains contactor status (open/closed, for TE809A and TE809Ats).
    • Fuel: Fuel percentage in the tank (for TE809A and TE809G).
    • kW: Active power. An example message shows the format of the returned data: VGen:400; 403; 400; FG:50; Vbat:12,3; h:100; Eng:1; Fuel%:100; KG:1; kW:23;.

Maintenance Features

The manual implicitly covers several maintenance-related aspects:

  • Installation and Connection Guidance: Detailed instructions for serial cable, antenna, and power connections ensure correct setup, which is fundamental for reliable operation and minimizes the need for troubleshooting.
  • SIM Card Management: The critical step of disabling the SIM card's PIN code before insertion is a key maintenance procedure to prevent communication failures. The manual advises testing the SIM in a mobile phone first to ensure it functions correctly and the PIN is disabled.
  • LED Diagnostics: The LED indicator serves as a primary diagnostic tool, allowing users to quickly identify potential issues such as SIM card problems, signal strength issues, or incorrect PIN settings, guiding them toward appropriate corrective actions.
  • Troubleshooting: The manual provides troubleshooting tips for common issues, such as persistent slow blinking of the LED, suggesting checks for SIM card presence, PIN status, and GSM signal strength.
  • Software Updates: While not explicitly detailed as a user-performable maintenance task, the manufacturer's right to modify equipment implies potential for firmware updates or improvements, which would typically be handled by authorized personnel or through specific update procedures not covered in this general user manual.
  • Technical Department Support: The manual directs users to consult the TECNOELETTRA Technical Department for any questions or further improvements, indicating a support channel for complex issues or advanced maintenance.

Overall, the TECNOELETTRA GSM modem is presented as a robust and user-friendly device designed to extend the control and monitoring capabilities of the TE809 system through convenient SMS-based communication. Its clear installation guidelines, diagnostic features, and comprehensive command set make it an effective tool for remote management.

tecnoelettra TE809 Specifications

General IconGeneral
Brandtecnoelettra
ModelTE809
CategoryModem
LanguageEnglish