Ash on the
floor around
the stove
Flue pipes are not air-
tight
Only to be done by an approved flue
fitter: Flues that are not airtight can harm
your health. Seal the pipe fitting immedi-
ately (use Loctite 598 or equivalent prod-
uct) and/or replace the pipes.
Broken, worn or dam-
aged door seal
Replace the seal. Only to be done by a
Tectro-approved technician
Stove in con-
stant mode,
the display
shows: "Eco"
The room temperature
desired by the user has
been reached
This is not an error. The stove is working in
eco mode. This mode can be changed with
the remote control
Display shows
"SERV"
No error. The stove re-
quires a service every 900
hours of operation. The
stove will simply continue
to work.
The stove requires a service. Contact a
Tectro-approved service technician. The
technician will carry out a service on the
stove and reset the notification.
Display shows
"Atte"
An attempt is being
made to start the stove
while it is still in the cool-
ing-down phase.
Wait until the cooling down phase has
been completed before trying to reignite
the stove.