9 Diagnostics and troubleshooting
A list of possible system errors is provided in the table.
Faults indicated by control elements are explained in the chapter “Description of the control
elements”.
A recommissioning of the device must only occur if it is ensured that the system is functionally
equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after
consultation with TEKA GmbH, by the personnel authorised by the operator.
Adhere to the instructions in the chapter "Safety instructions" and " Maintenance" when carrying out any
repairs. If in doubt, contact our TEKA service department:
Tel: +49 2863-9282-0
E-mail: info@teka.eu
Plug power supply is missing or
incorrectly inserted.
Plug connector check power
supply / plug in correctly.
Check the mains, remove error if
possible.
Dust at the service door
of the filter housing.
The door is not correctly closed.
The seal between the service door and
filter housing is damaged.
The seal must be replaced.
Escape of dust at the hinge.
The hinge must be reoriented or
replaced.
Suction power too low
(smoke hardly
extracted).
Filter element is saturated.
Replace the filter package,
dispose of old filter properly!
Damage at the extraction elements.
Replace the extraction elements.
The motor rotates in the wrong
direction.
The rotating field of mains
connection point must be
changed.
The system is very noisy.
The motor rotates in the wrong
direction.
The rotating field of mains
connection point must be
changed.
BA_Caremaster-1-und-2_IFA_170831 _EN