15
EN
contact separation. Suitable separation devices include e.g.
       ply
with current regulations.
If the electrical connection is done through a plug and this
remains accessible after installation, then it is not necessary to
provide the mentioned separation device.
The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air back into
the room).
The lower part of the extractor must be located at a minimum
height of 50 cm above the hob for electric cookers and 65 cm for
gas cookers. If the instructions of a gas cooker indicate a greater
distance these must be observed.
Before installing the extractor consult the local rules and
regulations in force with respect to the discharge of air and
fumes.
When the extractor is working at the same time as other non-
electrical cooking equipment, the outlet air pressure must not
exceed 4 Pa (4x10
-5
bar).
Before connecting the extractor to the mains, check that both the
voltage and the frequency conform to that shown on the
characteristics label located inside the extractor.
To achieve optimum performance the length of the outlet hose
should not exceed 4 meters or include more than two 90º angles
(elbows).
Although venting to the outside is recommended, activated
carbon filter may be used to allow the gas to be returned to the
kitchen through the outlet pipe.
NOTE: For more Installation information, refer to the end of this
user manual.
Cleaning
There is a fire risk if cleaning is not carried out in accordance
with the instructions.