Questions and Answers

  • L
    lopeznicoleSep 8, 2025
    Why is there no change in recovery volume in my Tektino RCC-6S-dual Refrigerator?
    • C
      christopherstewartSep 8, 2025
      The recovery volume might remain unchanged because there's no refrigerant in the A/C, in which case you should stop the recovery. Also, make sure that the support screw of the gas cylinder load cell is loosened, referring to chapter 'Operation preparations'. A faulty gas cylinder load cell or PCA failure could also be responsible; try calibrating the gas cylinder load cell, or replacing the load cell, or changing the PCA.
  • V
    Vincent RobinsonAug 23, 2025
    Why does my Tektino Service Equipment vacuum pump inject oil?
    • W
      williamwyattAug 23, 2025
      If your Tektino Service Equipment's vacuum pump is injecting oil, it could be due to two reasons. First, the oil volume might be too high; in this case, discharge some oil to the proper level. Second, the entrance pressure might be too high; try running the Recovery function first.
  • K
    Keith OwensAug 25, 2025
    How to fix low vacuum degree in Tektino Service Equipment?
    • T
      Tiffany CarterAug 25, 2025
      A low vacuum degree in your Tektino Service Equipment can stem from several issues: * Insufficient vacuum pump oil: Add oil to the central line. * Pump oil emulsion or dirt: Replace with new oil. * Plugged pump oil inlet: Clean the oil inlet. * Leakage in the pump connection: Check the connection. * Worn-out components: Maintain the machine, paying special attention to o-rings, washers, and other sealing parts.
  • J
    Jerry FordAug 26, 2025
    What to do if my Tektino Service Equipment recovery does not stop?
    • H
      Hannah WalkerAug 27, 2025
      If the recovery function on your Tektino Service Equipment doesn't stop, it could be due to a few reasons. There might be a leakage in the automotive A/C or equipment pipeline, so perform a leakage test, referencing the service manual for the machine leakage test. Alternatively, the compressor might not be working, requiring a replacement. Lastly, the pressure sensor could be faulty; try fastening the pressure sensor connection to the PCA or replacing the pressure sensor.
  • M
    Morgan LambertAug 27, 2025
    Why is there no change in recovery volume in my Tektino Service Equipment?
    • J
      Julie ChavezAug 27, 2025
      If you notice no change in recovery volume with your Tektino Service Equipment, consider these potential causes. First, there might be no refrigerant in the A/C; if so, stop the recovery process. Second, the support screw of the gas cylinder load cell might not be loosened; unscrew the protection screw, as described in the “Operation preparations” chapter. Third, the gas cylinder load cell might not be working, or there could be a PCA failure; try calibrating the gas cylinder load cell, or replace the load cell or PCA.
  • A
    Alexandra ObrienSep 22, 2025
    Why is there suction in the old oil bottle during vacuum in my Tektino RCC-6S-dual?
    • M
      Maria ThomasSep 22, 2025
      If you notice suction in the old oil bottle during vacuum, the contact between solenoid valve #2 and the valve base may not be well sealed. Remove solenoid #2 from the valve base and clean both the solenoid valve and valve base.
  • D
    Denise ChavezSep 16, 2025
    Why is my Tektino RCC-6S-dual Refrigerator not charging or charging slowly?
    • J
      jacksonwilliamSep 16, 2025
      If your Tektino Refrigerator is not charging or charging slowly, it could be due to insufficient refrigerant in the equipment. In this case, fill the equipment tank with more refrigerant. It may also be caused by a charge line problem. Check the charge line, including the tank red valve, tank red hose, solenoid #5, solenoid #9 (high side), solenoid #11 (long side), service hoses, and HP/LP quick couplers.
  • L
    Linda WagnerSep 18, 2025
    Why is there too much oil in the vacuum pump of my Tektino RCC-6S-dual?
    • L
      lauren85Sep 18, 2025
      If the vacuum pump is pressurized during recovery and there's too much oil in it, the contact between solenoid valve #8 and the valve base may not be well sealed. Remove solenoid #8 from the valve base and clean both the solenoid valve and valve base.
  • J
    Jamie GarciaSep 7, 2025
    What to do if my Tektino RCC-6S-dual Refrigerator shows no display?
    • C
      Christine CampbellSep 7, 2025
      If your Tektino Refrigerator display is blank, the fuse might be blown (either in the power cable connection box or on the PCA). Try changing the fuses. Alternatively, the PCA itself might be burnt, requiring replacement. A loose power cable could also be the culprit; ensure it's securely connected. If none of these solutions work, the LCD screen might be faulty and need replacement.
  • J
    James AndersonSep 4, 2025
    Why is there suction in the old oil bottle during vacuum with my Tektino Service Equipment?
    • K
      Kelly BradfordSep 4, 2025
      If you notice suction in the old oil bottle during vacuum with your Tektino Service Equipment, the contact between solenoid valve #2 and the valve base may not be well sealed. Try removing solenoid #2 from the valve base and cleaning both the solenoid valve and the valve base.

Summary

General Safety

Operation Preparations

Unlock Load Cells

Procedure to release load cells for tank weighing.

Fill Equipment with Refrigerant

Steps to initially charge the machine with refrigerant.

Select Refrigerant

Equipment Connection

Recovery

Vacuum

Oil Injection

Charge

Auto Mode

System Setting

Calibration

Process for calibrating load cells and other sensors.

Main Troubleshooting