EasyManuals Logo

Tektronix FG 504 User Manual

Tektronix FG 504
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
O
p
erati
n
g
I
n
st
r
uctions-
F
G
504
(S
N
Β
040000
&
UP)
control
ste
ps
.
Α
trigger
sig
n
al,
one
for
eac
h cycle
of
t
he
selecte
d
waveform,
is
available
at
t
h
e
T
R
IG
O
UT
PU
T
co
nn
ector
.
Wh
en
usi
ng
t
he
si
ne
or triangle
waveform
out
p
ut
wit
h
t
h
e
MUL
TI
PL
I
ER
in
t
he
slowest
five
p
ositio
n
s,
t
h
e
waveform
output
may
b
e
stopped by push
ing
t
he H
O
L
D
button
.
T
h
e
waveform
generator
sto
ps
a
nd
t
he F
G
504
outputs
α
do
voltage
equal
to
t
he
voltage
t
h
e
triangle or
si
ne
waveform
reac
hed
w
hen
t
h
e
button
was
pu
shed
.
T
h
is
feature
does
not
o
p
erate
on
t
he
s
q
uare
waveform
.
Wh
en
pulled
out,
t
he
SY
MME
T
R
Y
co
n
trol
d
ivides
t
he
output
fre
q
uency
(FRE
Q
=10
in
d
icator
lit)
by
te
n
,
and
varies
t
he
time
based
symmetry
of
t
he
selected
waveform
.
Pull
t
h
is
control
an
d
turn
for
t
he
desired
symmetry
u
si
ng
any
of
t
he
t
hree
basic
waveforms
.
Triggered
or
Gated
Operatio
n
W
it
h
t
he F
G
504
set for
free
running
o
p
eration
as
described
in
t
he
previous
paragrap
h
s,
ap
ply
the
triggering
or
gati
n
g
sig
n
al
to
t
he
I
NPU
T
connector
.
If
only
οη
e
cycle
of
t
h
e
outp
ut
waveform
p
er
trigger
is
d
esired,
pus
h
t
he
T
R
IG button
and
set
t
h
e
LEVEL
control
for
t
he
level
on
the
triggeri
ng
waveform
at
w
h
ic
h
t
he output
waveform
is
to
begi
n
.
If
more
t
han
one
cycle
of
t
h
e
output
waveform
is
desired,
press
t
he
GAT
E
pus
h
button
.
T
he
F
G
504
out
p
ut
now
begins
at
t
h
e
triggeri
ng
level
an d continues un
til
t
he
waveform
at
t
he
i
nput
co
n
nector
drops
below
t
he
trigger-
i
ng
level
.
T
he output
duration
is
now
t
he du
ration of
t
he
gating
waveform
.
The
number
of
cycles
p
er
b
urst
may
be
ap
proximated
by
d
ividing
t
h
e
gating
signal
duration
byt
he
perio
d
of
t
he F
G
504
outp
ut
fre
q
uency
. 1
η
t
h
e
gate
d
mode
of
operation,
t
he F
G
504
always
com
p
letes
t
he
last
cycle
.
If,
at
t
he
terminatio
n
of
t
he
gati
ng
waveform,
less
t
han
app
roximately
270°
of
t
he
last
cycle remain
s,
an
ad-
ditional
cycle
is
com
p
lete
d
.
in
triggere
d
or
gated
op
eratio
n
t
h
e
PHAS
E
control
varies
t
he
start
of
t
he
tria
n
gle
or
si
n
e
out
p
ut
waveform
by
±80°
.
T
h
is
p
h
ase
c
han
ge
is
measure
d
from
t
h
e 0
V,
p
oint
on
t
he
out
p
ut
waveform
.
To
ma
n
ually
trigger
or
gate
t
he
F
G
504,
tur
n
t
he
LEVEL
control
fully
cloc
k
wise
and
p
us
h
t
he
T
R
I
G
or
GAT
E
button
as
desire
d
.
In
t
he
TR
IG
mode,
pus
h
i
n
g
t
he
MAN
button
triggers
on
e
cycle
of
t
he outp
ut
waveforms
.
In
t
he
GAT
E
mode,
t
he
selecte
d
output
waveform
continues
as
lo
n
g
as
t
h
e
MAN
butto
n
is
p
ressed
i
n
.
V
oltage
Controlled
F
re
q
uency
Operation
T
he output freque
n
cy
of
t
h
e
F
G
504
ca n be
swe
p
t
over
α
frequency
range
of
1000
:1,
depe
nding on
t
h
e
MUL
TI
PL
I
ER
setti
n
g,
b
y a
pp
lying
α 0
V
to
10
V
signal
to
En
glis
h
2-6
t
he
V
C
F
I
NPU
T
con
n
ector
.
See
F
igure
2-3
for
t
he
max-
im
u
m
vcf
ra
n
ge
for
eac
h
MUL
TI
PL
I
ER
setti
n
g
.
It
may
be
necessary
to
vary
t
he
FRE
Q
UEN
CY
VERN
I
ER
control
to
obtai
n
t
he
full
1000
:1
swept range
or
t
he
lowest
swe
p
t
frequency
desire
d
.
ί7
Ζ
f-
ω
ω
l7
Ζ
α
σ
σ
ω
J
α
J
Σ
10
6
10
5
10
°
10'
10
2
10
-
' ~
10
-2
10
-
'-
C
ustom
positio
n
wit
h
factory
i
n
stalle
d
ca
p
acito
r
.
4
Hz
400
Hz
0
.4
Hz
:
4
0 Hz
0
.04
Hz
4
Ητ
0
.004
Hz
0
.4
Hz
0
.001
Hz
0
.04
Hz
4
kH
z
80
kH
z
40
MHz
400 Hz
400
kH
z
40
Hz
4
0
kH
z
20
Hz_
20
kHz
4 Hz
4 kHz
4
MHz
10
-
'
10
-2
10
-
'
1
10
10
2
10'
10
4
10
5
10
6
10'
10
8
Fr
eq
u
en
cy
Hz
Custom
Timing
R
a
n
ge
2028-03
F
ig
.
2-3
.
Graph
s
h
owi
n
g
r
ange
of
fre
q
ue
n
cies
f
o
r
each
MUL
TI
PL
I
ER
setti
n
g
t
h
at
can be
swept
wit
h α
0
to
10
V
sig
n
al
a
pp
lie
d
to
t
h
e
V
C
F
I
NPU
T
.
The p
olarity
of
t
he
vcf
in
p
ut
signal
determines
t
he
d irectio
n
t
h
e
output
fre
q
uency
is
swe
p
t
from
t
he
fre
quen
-
cy
set
by
t
he
MUL
TI
PL
I
ER,
FRE
Q
UEN
CY
H
z
(STA
R
T),
an d
FRE
Q
UEN
CYVERN
I
ER
controls
.
Α
p
ositive-going
voltage
raises
t
he
fre
quency
w
h
ile
α n
egative-goi
ng
voltage
lowers
t
he frequen
cy
.
Α
voltage
t
h
at
varies
symmetrically
about
0
V
swee
p
s t
he
out
p
ut
freque
ncy
symmetrically
about
t
h
e cen
ter fre
q
uency
d
etermi
ned by
t
he
fre
q
ue
n
cy
controls
(see
F
igure
2-3)
.
Si
n
ce
t
he
vcf
in
p
ut
am
p
litude
versus
frequency
is
α
linear
relatio
n
s
h
i
p
,
t
h
e
fre
q
uency
output
may
b
e
deter-
mine
d
from
t
he
vcf
input
amplitude
an
d
t
he
FRE
Q
UEN
CY
H
z
d
ial
p
osition
.
VC
Fsen
sitivityist
he
h
ig
h
est
possibledial
setti
n
g
(40)
times
t
he
MUL
TI
PL
I
ER
ra
nge d
ivided
by
t
he
maximum
V
C
F
input
voltage
(10
V
)
.I
n
t
he F
G
504,t
h
isisa
n
omi
n
al
sensitivity
(
H
z p
er
V)
.
of
4timest
he
MUL
TI
PL
I
ER
setting
.
F
or
example,
wit
h α
10'
MUL
TI
PL
I
ER
setti
n
g,
α
two-volt
ch
a
n
ge
at
t
he
V
C
F
I
NPU
T
will
ch
anget
h
e
output
fre
q
uency
8
kH
z
.
T
h
is
feature
permits
t
he user
to
install
α
custom
swe
p
t
freque
n
cy
range
.
T
he
.5
Χ
10'
position of
t
he
MUL-
REV
ΜΑΥ
1981

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix FG 504 and is the answer not in the manual?

Tektronix FG 504 Specifications

General IconGeneral
BrandTektronix
ModelFG 504
CategoryInverter
LanguageEnglish

Related product manuals