MODIFYING THE PAUSE TIME
MODIFYING THE PEDESTRIAN OPENING (motor mode 1)
The pause time is memorised duringthe time programmingprocedure. Tomodify this parameteronly, proceed as follows:
1- Press and hold Prog to reset, and use a screwdriver to short the jump Reset (detail 20 offig.1).
2- Keep the Prog key pressed.
3-After three secondsled LD3 (andthe flashing light)turns on. Programming procedure activated
4- Release the Prog key.
5-6 Press and hold P3 until led LD3 turns off.
7- Release P3, the led LD3 flashes and the pause time registrationphase is started.
8- Wait for the required time interval
9- Press P3 to block and memorise the pausetime.
Led LD3 turns offand the control unit exits programming mode.
P3 P3 P3
P3
LD3 LD3 LD3
Reset
P3
LD3
P3
P3
LD3
LD3
P3
LD3 LD3
PAUSE
Time