memorisation has been successful. The P2 output is now single-step.
The output has no magnetic hold, so if there is a power failure while
the relay is activated, the latter deactivates.
2.Timer output
- Press the key P2 3 times during programming.
- The led related to the pressed button gives 5 series of three blinks.
- During this stage, transmit with a transmitter from the TANGO range.
- A fixed led light for a few moments indicates that
memorisation has been successful. The P2 out-
put has now become a timer.
The timer is fixed for a time of approx. 30 sec-
onds and cannot be adjusted.
3.Code erasure
One or more codes may be erased from the memory of the receiver
with this operation.
- Press the key P1 or P2 4 times during programming.
- The led related to the pressed button gives 5 series of 4 blinks.
- During this stage, transmit with the radio control
from the TANGO range to be erased. A fixed led
light for a few moments indicates that erasure
has been successful.
4.Erasure of all codes (reset)
The receiver storage is totally erased by carrying out the reset.
- Press key P1 or P2 for at least 10 seconds until the button LEDs light
up simultaneously.
After a few seconds all the LEDs go out, indicat-
ing that erasure is complete.
- Repeat the memorisation procedure.