2
thetotalsecrecyofthecode.
-Thecodetransmissiontypeis“Rolling-code”.Thecodeischangedforevery
transmissionthroughtheuseofanalgorithmthatonlythereceiverisableto
recognize.
-InthereceivertheusercodeismemorisedunderEeprom,whichmaintainsthecode
informationevenwhenfacedwithblackouts(max.41code-memorisations).
Transmitters
Thetransmittersareencodedinthefactoryandeachtransmitterhasitsownunique
code.
Caution!Ifyoukeepachannelbuttonpresseddownformorethan30secondsthe
transmitterwillautomaticallyswitchoff.
ThereceiveriscompatiblewithalltransmittersoftheTVLinkrange:TVTXV,
TVTXP,TVTXC,TVTXK,TVTXQ,TVTXL,TVTXS.
To memorise codes from receiver
Mode 1
The memorisation or delete is made in the following way: channel 1 with channel
2 (or vice versa) and channel 3 with channel 4 (and vice versa)
Forsecurity,eachtimeyoucarryoutanewinstallation,youareadvisedtowipethe
entirememory(max.41differentcodes)
Theusercodeandtherelativechannelfunctionsarememorisedorcancelledviaradio
usingthefollowingprocedure:
1)PressandholddownP1,after0.8sthebuzzerB1willmake1bipandsound
continuously.
2)Transmitthechannelwhichistobememorised,thebuzzerB1willsound
intermittently.
Toinsertulteriorcodesrepeatpoints1and2.
Mode 2
The memorisation or delete is made in the following way: Single channels with
dynamic function, opening, stop, closing.
Forsecurity,eachtimeyoucarryoutanewinstallation,youareadvisedtowipethe
entirememory(max.41differentcodes)
Theusercodeandtherelativechannelfunctionsarememorisedorcancelledviaradio
usingthefollowingprocedure:
1)PressfortwotimesandholddownP1,after0.8sthebuzzerB1willmake2bip
andsoundcontinuously.
2)Transmitthechannelwhichistobememorised,thebuzzerB1willsound
intermittently.
Toinsertulteriorcodesrepeatpoints1and2.
To cancel a code from receiver: the delete happens in pairs like in the
memorisation mode 1 and 2:
1)PressandholddownthepushbuttonP2,after0.8sthebuzzerB1willswitchon
andsoundslowly.
2)Transmitthecodewhichistobecancelled,oncethechanneliscancelledthe
buzzerB1willsoundcontinuously.
Tocancelulteriorcodesrepeatpoints1and2.
To cancel all memorised codes:
1)PressandholddownP2foratleast0.8s,thebuzzerB1willsoundslowly,release
P2andpressitagainforatleast10s(duringthisperiodthebuzzerB1willsound
intermittentlyandquickly)asthebuzzerB1willsoundcontinuously.Releasethe
buttonaftercompletingtheoperation.
How to insert a transmitter via radio without accessing the receiver when the
memory is empty (rst installation), in this mode the channels function of the
transmitter will be in mode 1.
Thetransmittertobeinsertedwillbecomethemastertransmitterforinsertingother
transmitters.
1)PressP3ofthetransmitter,thereceiverwillactivatethememorisationandthe
buzzerwillsoundcontinuouslyfor5s.
2)Transmitthechannelwhichistobememorisedwithin5s.Oncethechannelis
memorisedthebuzzerwillsoundintermittently.
Attention:Whenmemoryisemptydonotgivepowertomorethanonereceiveratthe
sametime,becausetheabovementionedprocedureactivatesallreceivers.
How to insert a transmitter via radio without having to access the receiver by means
of an already memorized transmitter (memory indexing procedure)
Thetypeofmemorisationofthechannels(single,coupleor7-channel)dependsonhow
thechannel,whitchisusedinpoint2,hasbeenmemorized.
1)PressthebuttonP3locatedinsidethealreadymemorizedtransmitter.Theenabled
receiversoundcontinuouslyfor5seconds.
2)Transmitachannelpresentinthememoryofthereceiver,inwhichthenewcodeis
tobememorized,within5secondsandthebuzzerwillinterruptthesoundfor1sec,
andthencarryonforanother5seconds.
3)Transmitthenewchanneltobememorizedwithin5secondsandoncememorized
thebuzzerwillsoundintermittently.
Toinsertothertransmittersanothercoderepeatoperations1,2and3
Ifthereceiver’smemoryisfullitcannotbeenabledandthiswillbeindicatedbythe
buzzerB1soundingintermittently.
To cancel via radio a code through a transmitter already set in the memory:
1)PressP3forthreetimeswithin5s,thebuzzerB1willswitchonandsoundslowly.
2)Transmitthecodewhichistobecancelledwithin5s.Oncethechannelhasbeen
cancelledthebuzzerwillstopsounding.
Tocancelulteriorcodesrepeatpoints1and2.
Errors during the memorising
Ifthecodeisnotmemoriseditcouldbeduetothefollowingconditions:
-Thecodealreadyexistsinmemory
-Thememoryisfull(max.41codes).InthiscasetheBuzzerwillmake3bipeachtime
thepowerisswitchedonandduringthememorisation.
Antenna
Thecorrectinstallationandconnectionoftheantennaisfundamentalinorderto
obtainagoodrangefortheinstallation.
Connecta8.5cmpieceofwiretotheantennapoleconnectiononthedevice.
Asanalternative(andforbetterresults)useatunedantennaconnectedtothereceiver
viacoaxialcableRG58(impedance50Ω)withamaximumlengthof15metres
(mod.ANT868)
Technical specications
ReceiverRFsection
Receptionfrequency 868.3MHz
Intermediatefrequency 10.7MHz
Sensibility(nelytunedsignal) 1uV
Receivercodicationsection
Powersupply 230V
Operatingtemperaturerange -20°–+60°C
Maximumpoweratthemotor
Voltage 230V
Power 350W
Maximumcommutablepoweratoutputashinglamp 230V 60W
Maximumcommutablepoweratoutputcourtesylamp 230V 300W
Maximumcommutablepowerat24V output 80mA
Maximumcommutablepower
atterminalboards22-23 35V,1A
Intheviewofaconstantdevelopmentoftheirproducts,themanufacturerreservestheright
forchangingtechnicaldataandfeatureswithoutpriornotice.
Description of the connections:
1 Inputgroundgeneralpowersupply
2 Inputgroundmotor
3 Inputgeneralpowersupply230V
phase
4 Inputgeneralpowersupply230V
neutral
5 Outputrelaycontactopening
6 Output230V
neutralbymeansoffuse(commommotor)
7 Outputrelaycontactclosing
8-9 OutputLP230V
60Wmax.forashinglamp
10-11 OutputLC230V
300Wmax.forcourtesylamp
12 Output24V
80mAforphotocells
13 Output24V
pushbuttonsandsafetycommon
14 Pushbuttonsandsafetycommon
15 Openingpush-button,normallyopenedordynamicpush-button(seedip-
switchfunctions)
16 Closingpush-buttonnormallyopened
17 Stoppush-buttonnormallyopened
18 InputsafetydevicenormallyclosedFTC
19 Output12V
forOSE(max30mA)
20 InputsafetydeviceCSPresistive8,2Kohm
(range6Kohm-10Kokm)
21 Pushbuttonsandsafetycommon
22-23 Normallyclosedcontactforsafetytest
24 Antennamass
25 Antennapole(wire8.5cm)
We also wish to remind you that if the N.C. (normally closed) contacts are not
used they should be jumpered:
- If FTC input is not used, 18-22 and 23-21 contacts must be jumpered
- If CSP input is not used 20-21 must be jumpered, set J1 as n.c. and memorise
the buffer barrier as described at page 1
- If TB input is not used 17-21 must be jumpered
The earth wire must be longer of the other wires because it must be the last to
break off if the cable clamps slacking.
Remember that there are specic standards that must be complied with both
as regards the safety of the electrical systems and as regards the remote control
of tubular motors for roller blind.