This document describes the Tellur Flame Aroma Diffuser (TLL441121/TLL441131), a device designed to vaporize water and essential oils to produce a cool, dry, fragrant mist. It utilizes Ultrasonic Technology for its operation.
Function Description
The aroma diffuser's primary function is to disperse a fragrant mist into the air. It achieves this by using ultrasonic technology to vaporize water from its tank. Users can add essential oils to the water to create an aromatic environment. The device offers various mist output settings and light modes, enhancing its usability and ambiance.
Important Technical Specifications
- Voltage: AC100-240V / DC/24V 500MA
- Capacity: 240ml
- Max power: 14W
- Ultrasonic frequency: 2.4MHz
- Operation time: Up to 15 hours (approximately 12 hours for high mist, 15 hours for low mist)
- Vapor power: 16-20ml/h
- Vapor level: Light or powerful
- Light mode intensity: Strong (default), weak, breathing light
- Timer: ON/2H/4H
- Lighting: LED
- Low water protection: Auto shutdown
- Coverage area: Up to 30m²
- Power cord length: 150cm
- Color: White/Grey
- Product dimensions: 21013581mm
- Product weight: 479g
- Package includes: Aroma Diffuser, AC/DC Adapter, Remote control, Water cup, User Manual. Essential oils are not included.
Usage Features
The diffuser is designed for straightforward operation:
- Setup: Remove the top cover by lifting it vertically. Connect the AC adapter to the DC jack located at the base of the main body.
- Water Filling: Use the provided measuring cup to add water to the tank. It's crucial not to exceed the maximum water level line (240ml). Do not add hot water or water while the product is working.
- Cover Installation: Replace the top cover, ensuring it is correctly positioned for the device to operate.
- Mist Control: Press the "MIST" button to select the desired mist output (high mist, low mist) and set a timer (2H, 4H). A long press on the "MIST" button will turn off the device.
- Light Control: Press the "LIGHT" button to adjust the light mode and intensity. Options include strong light (default), weak light, and breathing light.
- Safety Features: The diffuser automatically turns off if there is a lack of water in the tank or when the water from the tank is finished. The power supply also automatically turns off when water runs out.
- Remote Control: The device comes with a remote control for convenience.
- ON/OFF button: Turns the device on or off.
- MIST button: Selects high mist output, low mist output, 2H, or 4H timer.
- LIGHT button: Adjusts the light mode (strong light, weak light, breathing light).
Maintenance Features
Regular maintenance is recommended to ensure optimal performance and longevity of the diffuser:
- Draining and Drying: If the diffuser will not be used for a long time, drain out the water and dry the tank.
- Cleaning the Tank: For reuse or after 3-5 days of use, unplug the unit and remove the top cover. Drain any remaining water. Add a small amount of warm water and kitchen detergent remover. Use a swab to gently wipe the tank, then dry lightly with a cleaning cloth.
- Preventing Water Flow into Air Outlet: When draining water, refer to the provided images to ensure water flows out from the designated drain side and does not enter the air outlet.
- Ultrasonic Plate Cleaning: If mist output is abnormal due to dirt on the Ultrasonic plate, refer to maintenance instructions to clean and reinstall it correctly.
- Air Suction Port Cleaning: If the air suction port on the underside of the base is dusty, clean it to prevent restricted mist output.
- Accidental Leakage: In case the device is knocked over, unplug it, remove the cover, drain remaining water, and gently shake the device to drain water. Allow it to dry for at least 24 hours.
Precautions and Safety Instructions
- Do not use acids or enzyme detergents, as these can produce poisonous gases or cause malfunctions. Use a mild detergent for cleaning.
- Do not fill over 240ml; a suggestion of ~200ml is provided.
- Do not switch on the power when the tank is empty.
- Do not touch the Ultrasonic vibration plate.
- Always unplug the device from the power supply before maintenance.
- For hygiene, after use, pour away remaining water from the DRAIN SIDE and wipe with a clean cloth.
- Wipe away essential oil spills immediately with a soft cloth to prevent staining.
- Only use the measuring water cup to add water; do not fill directly from a water pipe.
- Prevent mist from migrating onto furniture, clothing, or walls.
- Keep the device away from direct sunlight, heat sources, air conditioning, or fans.
- Place the diffuser on stable, flat surfaces; avoid carpets, duvets, or unstable areas.
- Keep it away from electronic equipment (TV, auto equipment).
- Do not tip the product during operation to prevent water from entering the mechanism and causing malfunction.
- Wait 60 minutes before restarting to avoid damage to the Ultrasonic plate.
- Use tap water only or distilled water.
- Never move the product when it is working.
- Do not touch any part of the product with wet hands.
- Keep out of reach of children and pets. Children should be supervised and not play with the product. The appliance is not suitable for unsupervised children or persons with reduced capabilities.
- Keep the cord clear of obstacles and do not pull it forcefully.
- If smoke or a burning smell is detected, unplug the device immediately.
Troubleshooting
- Will not switch on or switch off: Check if there is enough water in the tank and if the power cord is connected properly.
- No mist or abnormal mist: Check for sufficient water (not exceeding 240ml MAX), dirt on the Ultrasonic plate, or improperly installed top/inner covers. Also, check for dust in the air suction port. Low temperature or high humidity can cause mist to condense quickly into water droplets.
- Water leakage from the product: Ensure the top cover and inner parts are installed properly.