START-S3XL
START-S3XL-R_180914_VXX06_GB www.ebtechnology.it www.nologo.info
 Universal control unit for 1 sliding gate or up-and-over door.
 Motor, 3levels of slow down. Inputs: start-timer- clock, photocell during closing,
limit switch during opening and closing, partial opening, stop.
 Time acquisition “real-time”.
Radio receiver
-1-
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-9-
-10-
-11-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
230 Vac
230 Vac
Lamp
Lamp
MOT
common
MOT close
MOT open
+ Antenna
Com 1 and - Antenna
Com 2 / - 12/24Vdc
+ 12 Vdc
STOP
FOTO
LSO
LSC
START
Pedestrian
24 Vac
+ 24 Vac/dc
-20-
-21-
Light-Fototest
Light-Fototest
-22-
-23-
Mechanical edge - NC
Mechanical edge - NC
*
Connect this point to the terminal board no.
21 for the photo-test, otherwise connect it to
the terminal board no. 19
Photocells working
in closing
Lamp or courtesy light
230 Vac
If the input SAFETY-EDGE
is not used, make a link (22-23)
M
OP
CL
COM
*
N.C.
C
N.C.
N.C.
N.A. N.A.
100%
ITALY
24 V OUT24 V
TX
RX
Question and Answer IconNeed help?

Do you have a question about the telsiu altas START-S3XL and is the answer not in the manual?

telsiu altas START-S3XL Specifications

General IconGeneral
Brandtelsiu altas
ModelSTART-S3XL
CategoryReceiver
LanguageEnglish

Summary

Introduction

Safety Precautions

Essential safety guidelines for using and maintaining the control unit to prevent damage or voiding the warranty.

Installation

Control Unit and Electrical Connections Diagram

Detailed diagram showing the control unit's terminal layout and provides explanations for power supply and input/output connections.

Electrical Connection Description

Provides a detailed breakdown of each terminal's function, specifying input/output types and voltage requirements.

24 Vac Photocell Connection

Covers the connection of 24 Vac photocells, both with and without the TEST function, including DIP switch settings.

24 Vdc Photocell Connection

Details the connection of 24 Vdc photocells with and without the TEST function, emphasizing NC contact use.

Operating Logic for DIP Switches

Remote Control Management

Remote Control Learning

Provides a step-by-step guide for learning new remote control codes, including association with START and PEDESTRIAN commands.

Unit Operation and Programming

Learning START Opening Command Times

Guides the user through setting the opening times and deceleration points for the START command.

Learning PEDESTRIAN Command Times

Explains how to program the partial opening times and deceleration points for the PEDESTRIAN command.

Motor Force Regulation

Details how to adjust the motor force levels using the P button, with 7 available settings.

Resetting Construction Settings

Provides the procedure to reset the unit to its factory default settings using DIP1 and the P button.

Problem Solutions

Troubleshooting Common Issues

Offers solutions for common issues such as the unit not working, burnt fuses, or irregular operation.