EasyManua.ls Logo

Tenmars TM-507 - User Manual

Tenmars TM-507
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSULATION TESTER
TM-507
HB2TM5070000
Question and Answer IconNeed help?

Do you have a question about the Tenmars TM-507 and is the answer not in the manual?

Summary

1. SAFETY PRECAUTIONS AND PROCEDURES

1.1. PRELIMINARY INSTRUCTIONS

General safety and usage guidelines for the insulation tester.

1.2. DURING USE

Safety precautions and warnings for operating the instrument during measurements.

4. OPERATING INSTRUCTIONS

4.2. V: DC VOLTAGE MEASUREMENT

Step-by-step guide for measuring DC voltage with the instrument.

4.2.1. Anomalous cases which may occur during V measurements

Troubleshooting common issues or error displays during DC voltage measurements.

4.3. V: AC VOLTAGE MEASUREMENT

Step-by-step guide for measuring AC voltage with the instrument.

4.3.1. Anomalous cases which may occur during V measurements

Troubleshooting common issues or error displays during AC voltage measurements.

4.4. Ω): RESISTANCE MEASUREMENT AND CONTINUITY TEST

Instructions for performing resistance and continuity tests.

4.5. LoΩ: CONTINUITY TEST ON EARTH, PROTECTIVE AND EQUALIZING POTENTIAL CONDUCTORS

Guide for continuity testing of protective conductors with low resistance.

4.6. ΜΩ:INSULATION RESISTANCE MEASUREMENT TEST VOLTAGE 250 V, 500 V, 1000 V DC

Instructions for performing insulation resistance tests at different voltages.

Summary

1. SAFETY PRECAUTIONS AND PROCEDURES

1.1. PRELIMINARY INSTRUCTIONS

General safety and usage guidelines for the insulation tester.

1.2. DURING USE

Safety precautions and warnings for operating the instrument during measurements.

4. OPERATING INSTRUCTIONS

4.2. V: DC VOLTAGE MEASUREMENT

Step-by-step guide for measuring DC voltage with the instrument.

4.2.1. Anomalous cases which may occur during V measurements

Troubleshooting common issues or error displays during DC voltage measurements.

4.3. V: AC VOLTAGE MEASUREMENT

Step-by-step guide for measuring AC voltage with the instrument.

4.3.1. Anomalous cases which may occur during V measurements

Troubleshooting common issues or error displays during AC voltage measurements.

4.4. Ω): RESISTANCE MEASUREMENT AND CONTINUITY TEST

Instructions for performing resistance and continuity tests.

4.5. LoΩ: CONTINUITY TEST ON EARTH, PROTECTIVE AND EQUALIZING POTENTIAL CONDUCTORS

Guide for continuity testing of protective conductors with low resistance.

4.6. ΜΩ:INSULATION RESISTANCE MEASUREMENT TEST VOLTAGE 250 V, 500 V, 1000 V DC

Instructions for performing insulation resistance tests at different voltages.

Tenmars TM-507 Specifications

General IconGeneral
TypeDigital Multimeter
Temperature Range-20°C to 1000°C
Diode TestYes
Continuity BuzzerYes
Power Supply9V battery
DisplayLCD
DC Current Range200μA/2000μA/20mA/200mA/10A
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/2MΩ
Battery Test1.5V, 9V