16
that allows connection to either a masonry chimney or a prefabri-
cated factory made insulated metal chimney in accordance with their
instructions. In some cases it may be necessary to t an adaptor to
increase the diameter of the ue to the minimum required 150 mm
section of the chimney or liner.
Commissioning and handover
Ensure all parts are tted in accordance with the instructions.
On completion of the installation allow a suitable period of time for
any re cement and mortar to dry out, before lighting the stove.
Once the stove is under re check all seals for soundness and check
that the ue is functioning correctly and that all products of combu-
stion are vented safely to atmosphere via the chimney terminal.
On completion of the installation and commissioning ensure that the
operating instructions for the stove are left with the customer. En-
sure to advise the customer on the correct use of the appliance and
warn them to use only the recommended fuel for the stove.
Advise the user what to do should smoke or fumes be emitted from
the stove. The customer should be warned to use a reguard to BS
8423:2002 (Replaces BS 6539) in the presence of children, aged
and/or inrm persons.
READ THE INSTRUCTION BOOK AND THESE INSTRUCTIONS
CAREFULLY BEFORE USING THE STOVE
WARNING NOTE
Properly installed, operated and maintained this stove will not emit
fumes into the dwelling. Occasional fumes from de ashing and re
fuelling may occur. However, persistent fume emission is potentially
dangerous and must not be tolerated. If fume emission does persist,
then the following immediate action should be taken:
(a) Open doors and windows to ventilate the room and then
leave the premises.
(b) Let the re go out.
(c) Check for ue or chimney blockage and clean if required
(d) Do not attempt to relight the re until the cause of the
fume emission has been identied and corrected.
If necessary seek expert advice.
The most common cause of fume emission is ueway or chimney
blockage. For your own safety these must be kept clean at all times.
IMPORTANT NOTES
General
Before lighting the stove check with the installer that the installation
work and commissioning checks described above have been carried
out correctly and that the chimney has been swept clean, is sound