Safety Turtle
10
User Guide
®
Test each Turtle at points around the edge of the pool, including the point
furthest from the Base Station.The slow beeping sound should be heard
every time a Turtle is immersed at a depth of up to 4 inches (10 centimeters)
in the pool.Test each Turtle individually.
®
Immediately towel dry edges of Turtle to stop beeping.
Daily Use and Testing
With daily testing (following these instructions), the battery life of the Turtles will be
at least 3 years.
®
Ensure that the Base Station is plugged in and that the green light is on.
®
Ensure that each Turtle works by testing it as follows. Conduct all tests
with the Base Station at its actual operating location.
®
Set the Base Station to Test Mode by pressing the moon-shaped button
on the Base Station (the amber light will now turn on).
®
Immerse a Turtle in the pool at a depth of 4 inches (10 centimeters) and
verify that the Base Station is beeping slowly.
®
The volume of the test beep can be increased by holding down the moon-
shaped button. Once the desired volume is reached, release the button.
®
Immediately towel dry and shake Turtle.
®
Immediately following testing, press the moon-shaped button on the
Base Station to return to Active Mode (the amber light will turn off).The
Base Station will also automatically return to active mode 15 minutes after
Test Mode is entered.
®
A loud alarm will sound if Test Mode ends automatically while the Turtle
is still immersed.To continue testing, dry Turtle and after alarm stops press
the moon-shaped button to return to Test Mode.
®
The Base Station should be left in Test Mode only while a Turtle is being tested.
®
If the Base Station fails to alarm in either Test Mode or Active Mode,
or the Base Station emits a rapid beeping sound, discontinue use and see
the Troubleshooting section.