5.7.3 EMERGENCY STOP
Pressing the emergency stop in one of the connected machines generate the stop of the engine of the
single machine where the stop has been activated and the stop of the movement of all the remaining
connected machines, where the diesel engine remains switched on.
To reset the alarm, move the joystick to neutral on the master machine before to dis-engaged the
emergency stop on the machine in emergency situation.
5.7.4 CAN-BUS DIS-CONNECTION BETWEEN THE MACHINES
In case the connection cables between the machine may disconnect (ex. removing plugs, accidental
cutting of one cable, …), the stringing operations stops on all the connected machines.
To reset the alarm, move the joystick to neutral on the master machine and check the cause of the
fault.
5.7.5 ROPE-CLAMP POSITION
In case one of the rope-clamp is not completely open (electrical switch pressed and green light
switched on), none of the ropes can moves on all the connected machines.
5.7.6 GEAR-BOX LOW-PULL POSITION
In case one of the gear-boxes is in a low-pull position, (electrical switch pressed and green light
switched on), none of the ropes can moves on all the connected machines.
5.7.7 CONNECTION MACHINE SELECTOR
In case one of the connection machine selector is changed to off (leftwards) while connected machine
are running, all the machines will stop.
5.7.8 COMPONENT FAULT
In case of fault in one of the joystick & potentiometers component, the system switches on default
parameters with alarm indicator on control panel (L1 or L2).
In case of fault on pull adjusting solenoid valve the system only shows alarm indicator on control panel
(L1 or L2).