7.7 REDUCTION GEARS STATIONARY BRAKES COUPLER DIFFERENTIAL GEAR
MAINTENANCE
a. Change the oil of the reduction gears, stationary brakes, coupler and of the differential gear after
50 working hours and, then, every 500 hours (or every year at least).
b. To discharge the exhaust oil of the reduction gear and of the stationary brake, use the suitable
caps on the lower part of the casing of the same (table 3, pos. 6 and 11).
For the coupler use the suitable cap (table 2, pos. 16).
DANGER: let the hydraulic oil be completely cooled before removing it and always use the
suitable safety wears (gloves, etc.).
ATTENTION: the discharge of the exhaust oils has to be effectuated in conformity with the
laws in force in the relevant using country.
c. Fill the oil of the reduction gear and of the stationary brake by means of the suitable caps on the
upper part of the casing of the same (table 3, pos. 5 and 10).
For the coupler use the suitable cap (table 2, pos. 15).
ATTENTION: make maximum care when filling to make sure no foreign matter, which could
cause irreparable damages to the circuit’s components, enters along with the oil.
For further maintenance operations of installed mechanical components, refer to the enclosed
documentation.
7.8 RADIATOR’S MAINTENANCE
At least once a year, or more in case of use in dusty places, foreseen a blowhole with compressed air
of the radiant mass of the radiators.
ATTENTION: to carry out this operation the person in charge of the maintenance, besides
wearing all the protecting devices already described in this manual, has also to wear a device
for protecting respiratory organs.
7.9 GREASING
Grease 2-3 times per day the bull-wheels using the suitable lever (table 3, pos. 2); check the crowns
greasing from the timing case doors (table 3, pos. 1).
Weekly grease all the other parts subjected to sliding or rotation that not foreseen a forced lubrication
or an automatic greasing.
Use IP ATHESIA GR2 (ISO XBCEA 2) grease or equivalent of another trademark based on the
enclosed "SUGGESTED LUBRICANTS" table.
7.10 OTHER PERIODIC OPERATIONS
When cleaning the machine, avoid direct jets of water or steam on the components of the electric
system of the machine and on the control panel.
For other periodic operations, refer to the summary table for the ordinary maintenance (see next