Questions and Answers

  • J
    Julie VanceAug 20, 2025
    What to do if the motor is not operating in my Tetratec Aquarium?
    • M
      Mark MorenoAug 20, 2025
      If the motor of your Tetratec Aquarium is not operating, first ensure that the power is on. If the power is on, the impeller shaft may be broken and require replacement (consult your place of purchase). Alternatively, the impeller might be missing or clogged with foreign materials. In this case, set or clean the impeller.
  • J
    Julie BlackwellAug 31, 2025
    Why is there water leakage from the motor head of my Tetratec Aquarium?
    • T
      Terri LesterAug 31, 2025
      Water leakage from the motor head of your Tetratec Aquarium can occur if the lift buckles and/or safety buckles are not properly closed; ensure these are securely fastened. Foreign substances or dirt on the filter case or O-ring can also cause leaks; thoroughly clean these areas. Check the O-ring to ensure it is correctly placed, not damaged, and present. If the edge of the motor head is damaged, consider replacing it (consult place of purchase). Finally, ensure the hose adaptor unit is properly assembled.
  • P
    pottselizabethNov 10, 2025
    Why is there reduced water flow in my Tetratec Aquarium?
    • J
      Jasmine DonovanNov 10, 2025
      Reduced water flow in Tetratec Aquariums can occur for several reasons. The hose adaptor unit might be excessively dirty and needs cleaning under warm water. Hoses may be incorrectly connected, so ensure they are not entangled or crimped. Excessive dirt buildup in the hoses, a clogged water intake strainer, or clogged filter media can also restrict flow. If filter media is in nets or materials not supplied by the manufacturer, remove them. Improperly combined filter media should be checked against the manual. Dirty filter floss should be replaced, and dirt buildup in the impeller chamber cleaned. Ensure the return pipe is above the water surface during startup to remove air, and avoid using non-manufacturer accessories. Finally, ensure the motor head is at least 10 cm below the water surfa...

Tetratec EX 400 Specifications

General IconGeneral
TypeExternal Filter
Flow Rate400 L/h
Filtration Stages3
Pump output400 L/h
Hose Connection12/16 mm
Voltage220 - 240 V
Frequency50 Hz
Cable Length1.5 m
Media Includedceramic rings

Related product manuals