MADE IN ENGLAND
© 2017 Texecom Ltd
www.texe.com
-25°C to +60°C
425g approx.
-0°C to +40°C
Specications
Alarm System
EN50131-5-3, EN50131-1, PD6662, Grade
2 Class II
Product Type &
Frequency Band
GCEA1000 : 868.2 – 868.6MHz
GCEA3000 : 866.2 – 866.6MHz (Not CE
approved)
Receiver Category 1, Class 2
Receiver LBT Listen Before Talk
Transmitter Duty Cycle 868MHz<1%
Max RF power 10mW
Low Voltage Signal 2.4V
Operating Voltage 3V
Maximum Current 150mA
Quiescent Current 40uA
Relative Humidity 0 – 95% non-condensing
Proximity Reader 125khz proximity tag
Warranty
2 year replacement warranty (excludes batteries).
As the Premier Elite LCDLP-W is not a complete alarm system, but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on
a claim that the Premier Elite LCDLP-W failed to function correctly. Due to our policy of continuous improvement Texecom reserves the right to change specification without
prior notice.
Supplier: Texecom Ltd, Haslingden, Lancashire, BB4 4PW, UK.
WEEE Directive: 2012/19/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
Maintenance: Test yearly by the installer
Hereby, Texecom declares that the radio equipment type : GCEA1000(Premier Elite
LCDLP-W), is in compliance with Directive 2014/53/EU. The full EU declaration of
conformity is available here:
http://www.texe.com/cert/doc/DEC-T00281.pdf
Battery Safety
• Do not throw into a re • Do not heat • Do not disassemble
• Do not charge • Do not short circuit
• Replace with battery type Lithium AA 1.5V 2900mAh
• Always observe local regulations when disposing of a battery
• Keypad will transmit low battery warning when battery needs replacing
D
W
H
H = 118.8mm x D = 36.6mm x W = 149mm
OP1-
Tamp
Spk+
Spk-
+12v
Bell
0V
OP2-
AUX
Fault
Strb
DC+
L/M
R/R
DC-
2
3
5
6
7
8
4
1
+Batt-
+ - T R
AUX 0V
AUX 12V
Load Defaults
Jp1
Jp7
Fit for
Commission
Mode
Digi
Modem
Ricochet Monitor
Jp2
LED1
Digicom O/P’s
Tx Rx
Tx Rx
Wireless Eng Kpd
Jp6
Jp4
Com 1
Jp3
Com 2
Jp9
Kick Start
Expansion
Network Aux 12V Bell 12V
Enable
Smoke
Engineer REM
1
ON
2 4
3
OPTIONS
Tamper
Disable
100mV = 1 Amp
V
F3
F4
F5
F6
F1
F8
Batt Charge
0.75A 0.3A
F2
!
BAR CODE
USE WITH
TEXECOM PSU
ONLY
Z1 Z2 Z3 Z4
F7
OP1-
Tamp
Spk+
Spk-
+12v
Bell
0V
OP2-
AUX
Fault
Strb
DC+
L/M
R/R
DC-
2
3
5
6
7
8
4
1
+Batt-
+ - T R
AUX 0V
AUX 12V
Load Defaults
Jp1
Jp7
Fit for
Commission
Mode
Digi
Modem
Ricochet Monitor
Jp2
LED1
Digicom O/P’s
Tx Rx
Tx Rx
Wireless Eng Kpd
Jp6
Jp4
Com 1
Jp3
Com 2
Jp9
Kick Start
Expansion
Network Aux 12V Bell 12V
Enable
Smoke
Engineer REM
1
ON
2 4
3
OPTIONS
Tamper
Disable
100mV = 1 Amp
V
F3
F4
F5
F6
F1
F8
Batt Charge
0.75A 0.3A
F2
!
BAR CODE
USE WITH
TEXECOM PSU
ONLY
Z1 Z2 Z3 Z4
F7
Panel Connection
8. Keypad Menu
Using the Keypad menu you can change the following
• Pressing N & y together will show the
onboard keypad menu
• Press y to cycle through the options
• Press n to change an option
• Pressing y & n together will lock/unlock the
keypad if enabled
* Key press beep Select Beep, Click or none
* Locking allowed Yes or No - disables keypad
locking using y & n
* Power save mode Yes or No - disables power
save mode
Power save mode enables Tones that reduce the power
requirement and reduces the LCD backlight time.
6. Cable connection for Engineers keypad function
7. User Features
All features for the User are identical to the wired keypad with
the exception of the Prox operation:
• Press y to activate the keypad
• The Prox is active for 1-2 seconds