EN
Water leakage at the joint Check whether the sealing
ring is aging
Replace the sealing ring.
Fasten the joint of the air
duct.
Water leakage at the sprayer Check whether the sprayer
is cracked
The sprayer is below
the normal level during
operation
Replace the sprayer.
Raise the sprayer and
straighten the air duct.
Crack of handle Not well xed or damaged Re-buckle the handle or
replace the handle.
Abnormal noises in the air
duct
Check whether the air duct
is bent
The sprayer is below the
normal level
Straighten the air duct.
Raise the sprayer.
Deformation of kettle Check whether the water is
too hot
The kettle can be either used
or replaced.
Extension and removal of the
supporting bar
False operation Insert it again.
No steam, but the indicator
is on
The steam generator is
burnt.
The relay is out of work or
there is water deciency.
Professional maintainer is
suggested to check or add
water.
Alarm at the normal water
level
The oat is under water or
damaged.
Pull out of the oat or
replace it.
Without alarm when there is
water deciency
Machinery water tank
internal within too much dirt
Cleaning the water tank
Professional maintainer
suggested.
Buttons in the screen out of
work
Micro-computer malfunction
Reset is necessary.
Power o.
Then plug in.
Malfunctioning remote
control switch handle
Internal battery capacity low Replace handle low internal
battery
Texi Master Plus 37