EN
The company provides life-long maintenance service for the garment
steamer. The maintenance for the rst year will be free and the core will
be guaranteed to be maintained for 1 year without extra charge (except
for those damaged not due to quality problems.) As there is always the
sedimentation of water, hard water and water impurities inside and the
inner is kept under high temperature during operation, the carbonate waste
caused may gradually aect the heating procedure and the ironing. It is
advised to clean the inside of iron every three months so that it works at the
best condition.
Fouling cleaning in general: power o and take out of the rest water inside;
dissemble the clotes rack, air pipe and kettle. Get 400g clean water with a
vessel and a bag of exclusive detergent (lOg/bag); put all the detergent into
the vessel and then pour it into the sink after stirring (see the picture). (Note:
water position. Do not leak the water out of the iron) Put it for 3 hours and
pour the water out of the sink. Repeatedly add the water for cleaning.
If there is severe fouling, use 2-3 bags of exclusive detergent and dissolve
it in 400g clean water. Put it for 16 hours and then pour the water out of it.
Repeatedly add the water for cleaning.
MAINTENANCE
TROUBLESHOOTING
Fault Cause How to settle
Completely out of work Check the power
/the circuit fault
/the switch
Professional maintainer
suggested
Little steam Check whether the pipe is
blocked by the fouling and
whether the voltage is low
Use exclusive detergent for
cleaning.
Make the voltage stable.
Water pouring out of the
kettle
Check whether the kettle is
cracked or there is a hole in it
Replace the kettle.
Heating water in the kettle Check whether the pipe is
blocked
The air duct may be bent or
the sprayer sealed.
Eliminate the fouling or the
block.
Straighten the air duct and
do not seal the sprayer.