EasyManua.ls Logo

Theben RAMSES 811 top3 - User Manual

Theben RAMSES 811 top3
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
RAMSES 811 top3
8119200
RAMSES 812 top3
8120200
RAMSES 812 top3 16A
8120210
RAMSES 813 top3 HF
8139200
309952 00
28 February 2023
Digital clock thermostat
EN
1. General information
Digital clock thermostat for wall mounting or mounting
on ush-mounted box
The clock thermostat conforms with EN 60730-2-9 if
correctly installed
The RAMSES top3 series consists of 2 battery devices
(8119200, 8139200) and 2 power supply devices with
relay output of 10 A/16 A (8120200, 8120210)
External input to connect an external temperature
sensor, oor sensor etc.
Radio-controlled system RAMSES 813 top3 HF Set 1 and
Set A consisting of RAMSES 813 top3 HF and receiver
The RAMSES top3 app (for Android, iOS) allows settings
via mobile devices
Direct Bluetooth Low Energy (BLE) connection between
app and RAMSES top3 devices
Optional accessories: Floor sensor (9070321),
Temperature sensor RAMSES (9070459)
2. Safety
Assembly and installation should only be carried
out by a qualied electrician, somebody who has
completed appropriate professional training and
has the knowledge and experience necessary to be
able to recognise and avoid the potential dangers
posed by electricity.
Before installation/disassembly, disconnect the
supply voltage and ensure that the parts are no
longer live.
Prior to commissioning and using the product, read
and observe all the operating instructions.
3. Proper Use
Digital clock thermostat for time-dependent monitoring
and control of the room temperature in single-family
houses, ofces, etc.
Only operate the devices in dry indoor rooms (no bath-
rooms, etc.)
4. Installation
You can mount the clock thermostat either on the wall (not
8120210) or on a ush-mounted box.
Batteries
The devices RAMSES 811 top3 and RAMSES 813 top3 HF are
battery devices.
Only use AA batteries LR6, 2 x 1.5 V.
Ensure correct polarity.
Mount the clock thermostat
L For wall mounting. With RAMSES 813 top3 HF, a stand is
also included in the set.
!
Protect the clock thermostat from moisture, dust, direct
sunlight, thermal radiation and draughts.
!
On the battery devices (8119200 + 8139200), the termi-
nal box cover plate must be xed with the screws.
Position the clock thermostat on an interior wall, at about
eye level (approx. 1.50-1.60 m).
Fix the mounting plate directly to the wall or to a ush-
mounted box using the holes .
Assign and wire the conductors.
Insert the terminal box cover plate (top must point
upwards).
If necessary, tighten the screws and insert the batteries
correctly (only with 8119200 + 8139200) .
Put on the clock thermostat .
Dismount the clock thermostat
!
For battery change, open the device according to the
illustration, as it could be destroyed if not done so.
Insert the screwdriver into the opening and push up slightly
to open the device.
Electrician
Question and Answer IconNeed help?

Do you have a question about the Theben RAMSES 811 top3 and is the answer not in the manual?

Overview

The Theben RAMSES top3 series comprises digital clock thermostats designed for time-dependent monitoring and control of room temperature in single-family houses, offices, and similar dry indoor environments. These devices are available in battery-powered (RAMSES 811 top3, 813 top3 HF) and power-supply versions with relay outputs (RAMSES 812 top3, 812 top3 16A).

Function Description:

The RAMSES top3 thermostats regulate room temperature according to desired set times and offer three programmable weekly programs (P1-P3). Users can define and activate different operating modes:

  • Comfort temperature: Typically used during the day when occupants are present.
  • Setback temperature (Eco): An energy-saving temperature for nighttime or periods of absence.
  • Frost protection temperature: A minimum temperature to protect the heating system during prolonged absence (e.g., holidays).

The devices feature an external input for connecting various sensors, such as a floor sensor (9070321) or an external temperature sensor (9070459). The RAMSES 813 top3 HF models form part of a radio-controlled system for room temperature control, working in conjunction with receivers (e.g., REC 1, REC 11).

A key feature is the ability to configure settings via the RAMSES top3 app (for Android, iOS) using a direct Bluetooth Low Energy (BLE) connection. This app simplifies operation, allowing users to:

  • Set and manage weekly programs (up to 24 switching times per program, 42 total).
  • Create and activate holiday programs with specific start/end dates and temperatures.
  • Customize display settings, including brightness and backlight duration.
  • Adjust wall compensation (offset) to correct temperature variations due to installation location.
  • Enable window detection, which stops heating for 15 minutes if a window is opened in cold conditions.
  • Select between two controller types: Pulse Duration Controller (PDC) for precise regulation with low overshoot, or Hysteresis Controller (2-point control) for systems with larger thermal inertia.
  • Configure the external input for various sensors or contacts (floor, external temperature, presence detector, window contact, telephone contact).
  • Set an optimization function to pre-heat rooms, ensuring the desired temperature is reached at the programmed switching time.
  • Manage summer/winter time changeover rules (Central Europe, Western Europe, Eastern Europe, or inactive).
  • Assign or change a four-digit PIN for security.
  • Activate pump protection, which switches the heating circuit pump on for one minute weekly to prevent seizing.

For radio-controlled systems (RAMSES 813 top3 HF), the device and receiver are pre-matched. Users can perform a range test to optimize the placement of the thermostat and align the receiver antenna for optimal reception quality. New receivers can be encoded with the thermostat if needed.

Important Technical Specifications:

Battery Devices (8119200, 8139200):

  • Operating voltage: 2 x 1.5 V LR6 AA batteries.
  • Standby power: < 0.2 mW.
  • Power reserve during battery change: 10 min.
  • Time accuracy: ≤ ± 1 s/day (quartz) at 20 °C.
  • Controller type: Hysteresis controller or pulse duration controller.
  • Switch output: NO contact (8119200 only), floating.
  • Switching capacity: 8119200: 10 A at 250 V AC, cos φ = 1.
  • Operating temperature: +0 °C to +50 °C.
  • Temperature setting range: +2 °C to +30 °C in increments of 0.2 °C.
  • Memory locations: 42.
  • Protection rating: IP 40 (8119200), IP 20 during battery change (8119200).
  • Protection class: II (8119200 if correctly installed), III (8139200).
  • Control period: 5-30 min (pulse duration controller).
  • Control capture range: ± 0.2 K to 5 K (pulse duration controller).
  • Switching hysteresis: ± 0.2 K to ± 1.0 K (hysteresis controller).
  • Rated impulse voltage: 4 kV.
  • Radio frequency/transmission power: BLE 2.4-2.48 GHz, max. 2 dBm (approx. 40 m range in free field); 8139200: 868 MHz, max. 2 dBm (approx. 100 m range in free field).

Power Supply Devices (8120200, 8120210):

  • Operating voltage: 230-240 V AC, +6%/-15%, 50 Hz.
  • Standby power: < 0.2 W.
  • Controller type: Hysteresis controller or pulse duration controller.
  • Switch output: NO contact, floating.
  • Switching capacity: 8120200: 10 A at 250 V AC, cos φ = 1; 8120210: 16 A at 250 V AC, cos φ = 1.
  • Power reserve: 4 hours.
  • Operating temperature: +0 °C to +50 °C.
  • Temperature setting range: +2 °C to +30 °C in increments of 0.2 °C.
  • Memory locations: 42.
  • Protection rating: IP 40.
  • Protection class: II.
  • Rated impulse voltage: 4 kV.
  • Radio frequency/transmission power: BLE 2.4-2.48 GHz, max. 2 dBm (approx. 40 m range in free field).

Receiver REC 1 (9070461) (868 MHz):

  • Operating voltage: 230 V AC, +10%/-15%, 50 Hz.
  • Contact: NO contact floating, max. 6 (1) A/250 V AC per channel.
  • Protection rating: IP 20.
  • Protection class: II subject to designated installation.
  • Operating temperature: +0 °C to +50 °C.
  • Rated impulse voltage: 4 kV.

Receiver REC 11 (9070421) (868 MHz):

  • Operating voltage: 230 V AC, +10%/-15%, 50 Hz.
  • Contact: NO contact floating, 16 (2) A/250 V AC per channel.
  • Protection rating: IP 20.
  • Protection class: II subject to designated installation.
  • Operating temperature: +0 °C to +50 °C.
  • Rated impulse voltage: 4 kV.

Usage Features:

  • Installation: Can be mounted on the wall (except 8120210) or on a flush-mounted box. Battery devices require AA LR6 batteries (2 x 1.5 V) with correct polarity.
  • User Interface: Intuitive menu navigation via buttons on the device, complemented by the RAMSES top3 app for comprehensive control.
  • Display: Shows current time, actual temperature, and set temperature. Error codes flash with a warning triangle in case of faults. A battery symbol indicates low battery status.
  • Connectivity: Bluetooth Low Energy (BLE) for app connection. Radio-controlled (868 MHz) for RAMSES 813 top3 HF with receivers.
  • Safety: Conforms to EN 60730-2-9. Requires installation by a qualified electrician. Disconnect supply voltage before installation/disassembly. Protect from moisture, dust, direct sunlight, thermal radiation, and draughts. External input for 8120200 is not safely separated from mains; only insulated components should be connected.

Maintenance Features:

  • Battery Replacement: For battery devices, open the device carefully as illustrated to avoid damage. Low brightness and short backlight duration are recommended to extend battery life.
  • Cleaning: Use only a dry, soft cloth to clean the device surface. Avoid cleaning agents or solvents.
  • Troubleshooting: The manual provides solutions for common issues like forgotten PINs, Bluetooth connection problems, and heating not occurring at desired times. Error codes are displayed for easier diagnosis.
  • Reset: A hard reset (press + for 30 s) sets the PIN to 0000 for 5 minutes, allowing password changes. A soft reset (press + for 30 s) restores device name and last P1-P3, comfort, setback, and frost protection temperatures.
  • Factory Settings: All functions can be reset to factory settings via the app, which will interrupt the connection and restart the device.
  • Disposal: Batteries must be disposed of at municipal collection points. The device itself should be disposed of separately from domestic waste at an official collection point.