Step 4
Remove Motor
Now that the motor is free, remove the rotor and
impeller assembly from the stator.
Step 5
Begin the Cleaning Process
At this point, you may want to use a pair of latex or other
rubber-based gloves to protect your skin during the
cleaning process.
Liberaly apply Airmax D-Scale to the rotor and stator
(5a). You may even want to remove the spray tip from
the bottle and pour 6–8 ounces directly into the stator
and let it foam for 5–10 minutes in order to break
down any scale and buildup (5b). Use a Scotch-Brite
pad or abrasive sponge to thoroughly clean debris and
buildup on the rotor and inside the stator. Repeat as
needed until all debris and scale buildup is removed.
NOTE: Be sure to rinse all components with clean
water after using the D-Scale.
5a
5b
thepondguy.com | 866-POND-HELP (766-3435)
10
EXTENDED MAINTENANCE RAPIDFLO PUMP: