IMPORTANT INFORMATION:
Please read these instructions thoroughly before use. Failure to follow instructions may
result in equipment damage or failure, losses, injury or death.
DANGER:
• ALWAYS use a properly grounded AC outlet. Do not immerse the
RapidFlo plug in water or attempt to use a wet plug.
• Provide a drip loop” for the power cord. This is a loop in the cord
below the level of the receptacle or plug that prevents water
from traveling along the cord in the direction of the receptacle.
• Be sure that a ground fault circuit interrupter (GFCI) is installed
in the branch circuit supplying the pond equipment.
• NEVER remove the ground pin from the plug.
The RapidFlo is not suitable for use in swimming pools,
swimming ponds, or other situations where humans may make bodily contact with the water.
The power cable cannot be replaced. If the power cable becomes damaged, the RapidFlo
should be discarded.
• If an extension cord is necessary, a cord 14 gauge up to 100 ft. must be used. A cord may
overheat if the cord is rated for less amperes or watts then the unit rating.
WARNING:
For your protection, always unplug the unit from the power source before installing or servicing.
Should the unit appear to be not working, do not attempt to reach, remove, or disassemble
before disconnecting it from the power source.
To reduce the risk of electric shock:
• Do not remove cord and strain relief. Do not connect conduit to pump.
This pump has been evaluated for use with water only.
• Properly ground the unit to reduce the risk of electric shock.
This pump has not been investigated for use in swimming pool or marine areas.
• Do not connect to any voltage other than that shown on the pump.
• Always disconnect from electrical outlet before handling the pump.
• Operate pump completely submerged for proper cooling. Do not let the pump run dry.
IMPORTANT:
The Pond Guy is not responsible for equipment damage or failure, losses, injury
or death resulting from failure to follow safety precautions, misuse or abuse of
equipment.
TECHNICAL SPECS :
MODEL POWER WATTAGE
MAX FLOW
RATE
GPH @
5’ HEAD
GPH @
10’ HEAD
GPH @
15’ HEAD
MAX
HEAD
OUTLET
RapidFlo
3000
120v 60Hz 321 Watts 3,300 GPH 2,600 GPH 1,400 GPH 900 GPH 20’
2” FPT
or MPT
RapidFlo
4000
120v 60Hz 414 Watts 4,300 GPH 3,900 GPH 3,100 GPH 2,500 GPH 28’
2” FPT
or MPT
RapidFlo
5000
120v 60Hz 528 Watts 5,300 GPH 4,900 GPH 4,200 GPH 3,300 GPH 32’
2” FPT
or MPT
Power Cord
Drip Loop
thepondguy.com | 866-POND-HELP (766-3435)
2