Page 1
ABOUT THIS MANUAL
Signal Words for Safety and Best Use
WARNING
This indicates that death or serious injuries may occur as a
result of non-observance of this warning.
CAUTION
This indicates that minor or moderate injuries may occur as a
result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or property may
occur as a result of non-compliance with thisadvisory.
Note: This alerts you to important information and/or tips.
Pay special attention to the important safety instructions in the
“Safety” section.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
General notes
Note: Examine the appliance after unpacking it. In the event of
transport damage, do not plug it in.
Note: Do not remove any of the aluminum tape as it is needed for
sealing air leaks.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service
panel.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
Installation work and electrical wiring must be done by qualied
person(s) in accordance with all applicable codes and standards,
including re-rated construction.
Sufcient air is needed for proper combustion and exhausting
of gases through the ue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
CAUTION
To reduce the risk of re and electric shock, install this blower only with
Masterpiece
®
Series Downdraft Hood models shown below. Other
downdraft hood models cannot be substituted. (Downdraft hoods sold
separately).
Models UCVM30RS / UCVM36RS / UCVP36RS
FOR USE WITH
THESE DOWNDRAFT
MODELS
600 cfm Flexible Blower
Model VTD600P
Installation
MANUAL
Question and Answer IconNeed help?

Do you have a question about the Thermador VTD600P and is the answer not in the manual?

Summary

About This Manual

Signal Words for Safety and Best Use

Defines warning, caution, and notice signal words for safety and best use.

Compatible Downdraft Models

Compatibility Caution

Install only with specific Masterpiece Series Downdraft Hood models for safety.

Important Safety Instructions

General Notes and Handling

Examine appliance for damage, do not plug in if damaged. Keep aluminum tape for sealing.

General Safety Warnings

Observe precautions for unit usage, service panel lockout, and warning devices.

Installation Safety Warnings

Ensure qualified installation, proper ventilation for combustion, and avoid utility damage.

Additional Safety Instructions

General Usage Safety Precautions

Read instructions carefully to reduce risks of burns, shock, fire, and injury.

Proper Installation and Maintenance

Guidance on installation, maintenance, and safe operation of the appliance.

Filter Maintenance Caution

Grease on filters can melt and move into the vent. Clean filters regularly.

Sharp Edge Warning

Hidden surfaces may have sharp edges. Use caution when reaching behind or under the appliance.

Clothing Safety Warning

Tie long hair and avoid loose clothing to prevent entanglement hazards.

Appliance and Chimney Interaction Warning

Ensure adequate fresh air for combustion when using hood with other chimney appliances.

Carbon Monoxide Poisoning Warning

Provide adequate air intake to prevent back drafting of combustion gases.

Electrical Shock Prevention Warning

Switch off power at the service panel and lock it before installation.

Fire Safety Instructions

General Fire Safety

Use appliance as intended. Have smoke detector and extinguisher. Smother grease fires with soda.

Grease Fire Safety Procedures

Smother flames with lid, turn off burner. Never pick up flaming pan. Do not use water.

Extinguisher Usage Criteria

Use extinguisher only if trained, fire is small, department called, and back to exit.

Cooking Fire Hazards

Hot oil catches fire fast. Never leave unsupervised. Suffocate flames with lid or blanket.

Grease Filter Fire Risk

Grease deposits can ignite. Clean filter regularly. Never operate without a filter.

Flammable Material Warning

Avoid naked flames near appliance. Install near solid fuel appliances with closed covers.

Ductwork Fire Safety

Use only metal ductwork for exhaust systems.

Burn Hazard Warning

Accessible parts get hot during operation. Never touch hot parts. Keep children away.

Installation Protection Caution

Wear gloves and long sleeves to protect hands from abrasion during installation.

Gas Burner Fire Risk

Operate gas burners only with cookware on them to prevent appliance damage or fire.

Child Safety and Environmental Protection

Child Safety Responsibilities

Instruct children in safe practices. Ensure they do not climb or hang on appliance.

Cleaning Safety Precautions

Allow appliance to cool and grease to solidify before cleaning. Do not use steam cleaners.

California Proposition 65 Warnings

Product may expose you to chemicals known to cause cancer or birth defects.

Environmental Protection and Disposal

Dispose of packaging environmentally. Turn on appliance when cooking to avoid corrosion.

Corrosion and Humidity Risks

Avoid condensation buildup by turning on appliance when cooking. Prevent humidity ingress into electronics.

Cleaning Procedures and Surface Care

Clean stainless steel in grain direction. Do not use abrasive agents or wet cloths on controls.

Condensation Backflow Prevention

Install exhaust vent at a slight downward slope away from the appliance.

Parts Supplied

Parts Bag Contents

Lists components included in the parts bag for installation.

Plan the Installation

Direct to Downdraft Housing Installation

Instructions for mounting the blower directly to the Downdraft housing.

Inline Location Installation

Steps for installing the blower in an inline location like a cabinet or floor joist.

Install Flexible Blower in Remote Location

Remote Installation Requirements

Flexible blower must be within 4-feet of the Downdraft's electrical panel.

Mounting Bracket Installation

Attach mounting brackets to the flexible blower using specified screws.

Blower Mounting

Mount the flexible blower to a cabinet, floor joist, or framework with screws.

Duct Connection

Connect 8-inch round duct from housing to blower inlet and from outlet to roof/wall cap.

Strain Relief and Wiring

Use strain relief bushing for wiring connections to the electrical panel.

Thermador Support

Customer Service Contact

Contact STAR Customer Support for questions or service needs.

Parts and Accessories Purchase

Information on purchasing parts, filters, cleaners, and accessories online or by phone.

Thermador VTD600P Specifications

General IconGeneral
BrandThermador
ModelVTD600P
CategoryBlower
LanguageEnglish