7
BOILER MODEL RANGE
ELECTRICAL
SUPPLY (volts/Hz/phase) Blower Motor (hp)
Nominal power draw
(amps)
EVS-2000/2000S
120/60/1
1-1/2
7.5
208/60/1 6.6
230/60/1 6.4
208/60/3 6.0
230/60/3 6.0
460/60/3 3.0
Figure 1c: Dimensions and capacities EVS 2000 & 2000S
61.4
[1558.9]
13.9
[352.4]
7.0
[177.8]
9.6
[242.9]
2.3
[57.2]
19.0
[482.6]
4.4
[111.1]
17.9
[454.0]
31.0
[787.4]
3.5
[88.9]
6.3
[158.8]
23.6
[600.1]
21.8
[552.5]
REQUIREMENT
FOR BURNER
REMOVAL
91.8
[2332.0]
28.3
[717.6]
30.3
[768.4]
9.3
[235.0]
27.4
[696.9]
6.1
[155.6]
31.0
[787.4]
P&T GAUGE
WATER FLOW
SWITCH
RELIEF
VALVE
11.8
[298.5]
10.0
[254.0]
CONDENSATE
DRAIN
5
8
" TUBE
FLUE OUTLET
6" SAF-T-VENT
WATER RETURN
FROM SYSTEM 3" NPT
WATER SUPPLY
TO SYSTEM
3" NPT
GAS PILOT
1
4
" TUBE
GAS VENT
3
4
" NPT PIPE
70.5
[1790.7]
38.1
[968.2]
40.1
[1019.0]
19.6
[496.8]
4.0
[102.4]
5.0
[126.2]
8.5
[215.1]
5.9
[149.2]
26.2
[666.7]
7.0
[178.6]
14.4
[365.9]
19.0
[481.8]
2.2
[55.5]
6.9
[174.6]
18.6
[471.4]
20.9
[531.8]
22.4
[569.9]
23.4
[595.3]
REQUIREMENT
FOR BURNER
REMOVAL
13.0
[330.2]
39.6
[1004.8]
40.8
[1036.3]
P&T GAUGE
WATER FLOW
SWITCH
RELIEF
VALVE
13.3
[337.8]
10.5
[266.7]
BOILER DRAIN
1" NPT PIPE
FLUE OUTLET
6" SAF-T-VENT
WATER RETURN
FROM SYSTEM 4" NPT
INLET AIR
8" GALVANIZED
DUCT
WATER SUPPLY
TO SYSTEM
4" NPT
GAS SUPPLY 1
1
2
" NPT
GAS PILOT
1
4
" TUBE
GAS VENT
3
4
" NPT PIPE
EVS-2000
EVS-2000S
Boiler Model
Number
CAPACITIES
INPUT
(MBH)
GROSS
OUTPUT
(MBH)
NET AHRI
RATING
(MBH)
2
WATER
VOLUME
(gallons)
DRY WEIGHT
(lbs.)
WET WEIGHT
(lbs.)
EVS-2000 2,000 1,696 1,475 18.5 1,461 1,615
EVS-2000S 2,000 1,732 1,506 40.1 1,835 2,169
Notes:
1. Piping removed
for visual clarity
(rear view).
2. See notes
concerning Net
AHRI Ratings on
page 4.