OPERATION
INSTRUCTIONS
MINI-SPLIT
HEAT PUMP
FOR MODELS:
MS412HP13240A
MS418HP13240A
950-0023-REV-F 12-19-06

Questions and Answers

Summary

Safety and Operation Notes

Safety Precautions

Essential safety guidelines including grounding, power handling, unit placement, and water exposure.

Operational Guidelines

Key rules for operating the air conditioner efficiently and safely, like temperature settings and ventilation.

Unit Parts and Features Overview

Indoor Unit Components

Identification of key parts of the indoor unit, including display, louvers, and controls.

Outdoor Unit Components

Identification of key parts of the outdoor unit, including air inlets, outlets, and connections.

Remote Control Functions and Indicators

Remote Control Operation

Details on using buttons like MODE, FAN, TEMP, SWING, SLEEP, TIMER, and CANCEL for operation.

Remote Control Display

Explanation of the LCD screen and indicators for displaying air conditioner status.

Operational Remarks

Notes on operational delays and power failure behavior recall.

Operation Guide

Remote Battery Installation

Instructions for inserting AAA batteries into the remote control.

Remote Control Usage

Proper usage of the remote, including aiming, range, and selecting modes.

Fan and Louver Control

How to set fan speed, control louver swing, and manage airflow direction.

Sleep and Timer Functions

Steps to activate and customize sleep mode and set programmable timers.

Care and Maintenance

Cleaning the Cover Panel

Procedure for safely cleaning the indoor unit's cover panel.

Cleaning Air Filters

Recommended steps for cleaning the air filters for optimal performance.

Troubleshooting Common Issues

System Not Operating

Diagnosing and resolving issues when the system fails to start or operate.

Unusual Odors

Identifying causes and solutions for unusual smells from the indoor unit.

Noise Issues

Troubleshooting minor noises like liquid sounds or creaking from the unit.

Remote Control Malfunction

Resolving problems where the remote control does not respond or function correctly.

Overview

This document provides operation instructions for a Mini-Split Heat Pump, specifically for models MS412HP13240A and MS418HP13240A. It covers safety guidelines, unit features, remote control functions, an operation guide, maintenance procedures, and troubleshooting tips.

Function Description

The Mini-Split Heat Pump is designed to provide heating and cooling for a room, offering a versatile solution for maintaining comfortable indoor temperatures. It operates as a heat pump, meaning it can both cool a space by removing heat and heat a space by transferring heat indoors. The system consists of an indoor unit and an outdoor unit, connected by piping and wiring. The indoor unit is responsible for distributing conditioned air into the room, while the outdoor unit manages the heat exchange with the external environment. The system is controlled via a remote control, allowing users to adjust various settings such as mode, temperature, fan speed, and timer functions.

Usage Features

The operation of the Mini-Split Heat Pump is primarily managed through a remote control, which needs to be pointed at the receiver on the indoor unit. The remote control has an operating range of approximately 22 feet.

Modes of Operation:

The system offers several operating modes:

  • COOL Mode: In this mode, the system cools the room to satisfy the set temperature.
  • HEAT Mode: The system heats the room to satisfy the set temperature.
  • AUTO Mode: The system automatically determines the appropriate operation mode (cooling or heating) based on the room temperature in the vicinity of the indoor unit.
  • FAN Mode: In this mode, only the fan operates, circulating air without heating or cooling. The fan runs continuously at the selected speed unless the temperature setting is satisfied.
  • DRY Mode: This mode is designed for dehumidification. Cooling runs periodically with a low-speed fan to reduce humidity in the room. Heating does not operate in this mode.

Temperature Setting:

In COOL, DRY, FAN, or HEAT modes, the temperature can be set using the TEMP+ and TEMP- buttons on the remote control. The temperature range is typically from 61°F to 86°F.

Fan Speed Control:

The FAN button on the remote control allows users to select different fan speeds: AUTO FAN, LOW speed fan, MEDIUM speed fan, and HIGH speed fan. In AUTO FAN mode, the system automatically selects the proper fan speed to satisfy the temperature setting. If a specific fan speed is selected, the fan will operate continuously at that speed.

SWING Operation:

The SWING button controls the automatic rotation of the louvers, which helps circulate air throughout the room. Pressing the button once initiates automatic rotation, and pressing it again stops the louvers at a specific position to control the direction of airflow.

SLEEP Mode:

This feature allows the system to gradually adjust the temperature setting over a specified period, typically for nighttime comfort. To activate, turn the unit on, press the SLEEP button, then use the TIMER OFF button to set the scheduled length of time (in half-hour increments from 0.5 to 24 hours). The + or - buttons are used to specify the final temperature setting for SLEEP mode. Once set, the unit will gradually adjust the temperature until both the final temperature and set time are reached, after which the unit automatically turns off.

TIMER Operation:

The system includes TIMER ON and TIMER OFF functions.

  • TIMER OFF: When the system is "On," pressing the TIMER OFF button repeatedly allows users to set a scheduled length of time (in half-hour increments from 0.5 to 24 hours) before the system turns off.
  • TIMER ON: When the system is "Off," pressing the TIMER ON button repeatedly allows users to set a scheduled length of time (in half-hour increments from 0.5 to 24 hours) before the system turns on.

Remote Control Batteries:

The remote control requires two (2) AAA batteries. To install, slide open the battery compartment cover, insert the batteries ensuring correct polarity, and then slide the cover back into place.

Safety Precautions:

Several safety notes are emphasized. The unit requires proper earth grounding by a certified technician; never connect it to gas pipes, drain pipes, or incorrect grounding systems. The power supply should be cut off when the air conditioner is not in use for extended periods. Users are advised not to attempt repairs themselves, avoid placing space heaters near the unit, and ensure that air intake and outlet vents are not blocked. Combustible sprays should be kept away. If a stand is used for the outdoor unit, it must be firm enough to support its weight. Splashing water on the unit can cause electric shock or malfunction. The air conditioner should operate within a stable voltage range of 208-230V 1PH, as unstable supply can cause vibration and damage.

Operation Precautions:

Users should set the room temperature appropriately and avoid leaving windows and doors open for long periods while the unit is operating. The unit should not be operated without an air filter or when the front cover is removed. The remote controller should not be stored in direct sunlight or excessive heat, dropped, thrown, or immersed in liquids.

Maintenance Features

Regular maintenance is crucial for the optimal performance and longevity of the Mini-Split Heat Pump. Always disconnect power before performing any cleaning or maintenance.

Cleaning Cover Panel:

  1. Open the cover panel.
  2. Wipe the cover panel with a damp cloth using warm water or a mild cleaner, then allow it to air dry. Never use hot water.
  3. Replace the cover panel by inserting the tab support on either end into the supporting slots on the unit, then close and latch the cover.

Cleaning Air Filters:

Air filters should be cleaned approximately once every three months under normal conditions.

  1. Open the cover panel.
  2. Using the tab at the bottom of the filter, lift and remove it in the direction of the arrows shown in the diagram.
  3. Clean the filters using a vacuum cleaner or by washing them with warm water, then allow them to air dry. Never use hot water.
  4. Replace the filters by inserting them as shown in the diagram, then close and latch the cover panel.

Troubleshooting:

The manual includes a troubleshooting section to address common issues. For instance, if the system does not operate, potential causes include disconnected power, the system being turned off, a 3-minute delay after turning off (to protect the system), a tripped circuit breaker, or "TIMER ON" being displayed. Unusual odors can be caused by odors trapped in the air filter, requiring filter cleaning. Slight liquid noises are normal and caused by refrigerant flowing inside the unit. Slight creaking noises are due to the expansion and contraction of plastic materials from temperature changes. If the remote control does not operate, check if batteries need replacement, if it's within operating range, if it's pointed towards the receiver, or if there are obstructions. If functions are frequently changed or the unit is disturbed, disconnecting and reconnecting power to the indoor unit may restore remote control operation. Always turn off the fan control and remove the unit plug from the wall outlet before any inspection or maintenance work to reduce the risk of electric shock or injury.

Thermal Zone MS412HP13240A Specifications

General IconGeneral
BrandThermal Zone
ModelMS412HP13240A
Phase1
RefrigerantR410A
Voltage208/230V
TypeHeat Pump