Heat Pump Manual
10
TECHNICAL DATA
AIR TO WATER HEAT PUMPS
Model
THW20 and THWDW20
Nominal heating capacity
–
kW
20
Rated duty point
–
in red
20°C Ambient conditions 45°C Water supply 60% RH
Water Supply Temperature
45°C
50°C
55°C
60°C
65°C
70°C
Heating Capacity – kW 10°C Ambient
18.62
18.18
17.78
17.40
17.25
17.13
Power Input
4.77
5.28
5.83
6.40
6.63
6
.81
COP
3.90
3.44
3.05
2.72
2.60
2.51
Heating capacity – kW 20°C Ambient
21.86
21.27
20.67
20.07
19.83
19.64
Power Input
4.81
5.32
5.87
6.47
6.71
6.90
COP
4.54
4.00
3.52
3.10
2.96
2.85
Heating Capacity – kW 30°C Ambient
25.50
24.71
23.92
23.17
22.87
22.63
Power Input
4.80
5.31
5.87
6.47
6.71
6.90
COP
5.31
4.65
4.07
3.58
3.41
3.28
Model
THW30 and THWDW30
THW30H and THWDW30
Nominal heating capacity
–
kW
30
Rated duty point
–
in red
20°C Ambient conditions 45°C Water supply 60% RH
Water Supply Temperature
45°C
50°C
55°C
60°C
65°C
70°C
Heating Capacity – kW 10°C
Ambient
25.50 24.85 24.10 23.45 23.19 22.98
Power Input
6.30
7.05
7.80
8.55
8.85
9.09
COP
4.05
3.52
3.09
2.74
2.62
2.53
Heating capacity – kW 20°C Ambient
29.30
28.45
27
.50
26.45
26.03
25.69
Power Input
6.30
7.05
7.80
8.55
8.85
9.09
COP
4.65
4.04
3.53
3.09
2.94
2.83
Heating Capacity – kW 30°C
Ambient
33.40 32.30 31.15 29.80 29.26 28.83
Power Input
6.30
7.00
7.75
8.50
8.80
9.04
COP
5.30
4.61
4.02
3.51
3.33
3.19
Model
THW40 and THWDW40
THW40H and THWDW40H
Nominal heating capacity
–
kW
40
Rated duty point
–
in red
20°C Ambient conditions 45°C Water supply 60% RH
Water Supply Temperature
45°C
50°C
55°C
60°C
65°C
70°C
Heating Capacity – kW 10°C Ambient
32
.70
31.95
30.90
29.95
29.57
29.27
Power Input
8.20 9.25 10.30 11.25
11.63 11.93
COP
3.99
3.45
3.00
2.66
2.54
2.45
Heating capacity – kW 20°C Ambient
39.05
37.10
36.00
34.70
34.18
33.76
Power Input
7.55
9.30
10.30
11.50
11.98
12.36
COP
5.17
3.99
3.
50
3.02
2.85
2.73
Heating Capacity – kW 30°C Ambient
43.90
42.85
41.30
40.20
39.76
39.41
Power Input
8.40
9.35
10.30
11.50
11.98
12.36
COP
5.23
4.58
4.01
3.50
3.32
3.19