TECHNICAL DATA
AIR TO WATER HEAT PUMPS
All units have a details data sheet available – the information supplied below is
intended as a guide only – please contact Thermex for a copy of the individual model
data sheets
Model
THW07
Nomina
l heating capacity
–
kW
7
Rated duty point
–
in red
20°C Ambient conditions 45°C Water supply 60% RH
Water Supply Temperature
45°C
50°C
55°C
60°C
65°C
70°C
Heating Capacity – kW 10°C Ambient
5.48
5.37
5.27
5.19
5.16
5.13
Power Input – kW
1.51
1.6
7
1.85
2.05
2.13
2.19
COP
3.63
3.22
2.85
2.53
2.42
2.34
Heating capacity – kW 20°C Ambient
6.43
6.27
6.10
5.99
5.95
5.91
Power Input – kW
1.53
1.69
1.88
2.08
2.16
2.22
COP
4.20
3.71
3.24
2.88
2.75
2.66
Heating Capacity – kW 30°C Ambient
7.52
7.
31
7.12
6.92
6.84
6.78
Power Input – kW
1.54
1.71
1.90
2.10
2.18
2.24
COP
4.88
4.27
3.75
3.30
3.14
3.02
Model
THW10 and THWDW10
Nominal heating capacity
–
kW
10
Rated duty point
–
in red
20°C Ambient conditions 45°C Water supply 60% RH
Water Supply Temperature
45°C
50°C
55°C
60°C
65°C
70°C
Heating Capacity – kW 10°C Ambient
8.11
7.94
7.79
7.65
7.59
7.55
Power Input – kW
2.19
2.43
2.69
2.97
3.08
3.17
COP
3.70
3.27
2.90
2.58
2.46
2.38
Heating capacity – kW 20°C Ambient
9.51
9.27
9.05
8.83
8.74
8.67
Power Input – kW
2.21
2.45
2.72
3.01
3.13
3.22
COP
4.30
3.78
3.33
2.93
2.80
2.69
Heating Capacity – kW 30°C Ambient
11.15
10.84
10.51
10.22
10.10
10.01
Power Input – kW
2.23
2.48
2.74
3.04
3.16
3.26
COP
5.00
4.37
3.84
3.36
3.20
3.07
Mo
del
THW12 and THWDW12
Nominal heating capacity
–
kW
12
Rated duty point
–
in red
20°C Ambient conditions 45°C Water supply 60% RH
Water Supply Temperature
45°C
50°C
55°C
60°C
65°C
70°C
Heating Capacity – kW 10°C Ambient
10.59
10.39
10.29
9.86
9.6
9
9.55
Power Input – kW
2.69
2.99
3.34
3.71
3.86
3.98
COP
3.94
3.47
3.08
2.66
2.51
2.40
Heating capacity – kW 20°C Ambient
12.41
12.16
11.91
11.69
11.60
11.53
Power Input – kW
2.71
3.01
3.35
3.74
3.90
4.02
COP
4.58
4.04
3.56
3.13
2.98
2.87
Heating Capacity – kW 30°C Ambient
14.55
14.20
13.83
13.51
13.38
13.28
Power Input – kW
2.75
3.05
3.38
3.76
3.91
4.03
COP
5.29
4.66
4.09
3.59
3.42
3.29