INSTRUCTIONS
Pierce Biotechnology
PO Box 117
(815) 968-0747
thermofisher.com
3747 N. Meridian Road
Rockford, lL 61105 USA
(815) 968-7316 fax
Number Description
89877 Zeba Spin Desalting Columns, Micro (75µL), 25 columns, for 2-12µL samples
89878 Zeba Spin Desalting Columns, Micro (75µL), 50 columns, for 2-12µL samples
89882 Zeba Spin Desalting Columns, 0.5mL, 25 columns, for 30-130µL samples
89883 Zeba Spin Desalting Columns, 0.5mL, 50 columns, for 30-130µL samples
89889 Zeba Spin Desalting Columns, 2mL, 5 columns, for 200-700µL samples
89890 Zeba Spin Desalting Columns, 2mL, 25 columns, for 200-700µL samples
89891 Zeba Spin Desalting Columns, 5mL, 5 columns, for 500-2000µL samples
89892 Zeba Spin Desalting Columns, 5mL, 25 columns, for 500-2000µL samples
89893 Zeba Spin Desalting Columns, 10mL, 5 columns, for 700-4000µL samples
89894 Zeba Spin Desalting Columns, 10mL, 25 columns,
for 700-4000µL samples
89807 Zeba Spin Desalting Plates, 96-well, 2 plates
89808 Zeba Spin Desalting Plates, 96-well, 4 plates
Note: These products are recommended for processing compounds > 7000Da. The resin slurry is
supplied in 0.05% sodium azide.
Storage: Upon receipt store at 4°C. Product shipped at ambient temperature.
Introduction
The Thermo Scientific™ Zeba™ Spin Desalting Columns contain a high-performance resin that offers exceptional desalting
or buffer-exchange for protein samples. Samples volumes between 2µL-4mL and containing as low as 20µg of protein/mL
can be processed with unsurpassed protein recovery and 95% retention of salts and other small molecules (< 1000Da).
These columns require no chromatography system. The spin-column method eliminates waiting for samples to emerge by
gravity flow and the subsequent monitoring of fractions for protein recovery.
Important Product Information
The Zeba Spin Desalting Columns and Plates contain a size-exclusion chromatographic resin to separate proteins from
small molecules. As with all size exclusion-based separation, the amount of small molecule removed and protein
recovered are affected by the nature of the molecules and volume of sample. The sample volumes recommended provide
exceptional removal of a variety of small molecules (typically > 95% for molecules < 1000Da); however, proteins and
small molecules often behave differently than predicted because of a variety of factors such as hydrophobicity,
secondary structure and interactions. Therefore, some optimization of sample volume might be required to achieve
optimal performance for each specific sample. In general, reducing the sample volume added to the column increases
small molecule removal, and increasing sample volume maximizes protein recovery.
Also available are Zeba Spin Desalting Columns and Plates with a 40K MWCO, which enable removal of salts and other
small molecules < 2000Da and recovery of proteins and other macromolecules > 40,000Da.
Pub. No. MAN0015751
Pub. Part No. 2162579.1
Rev A.0

Questions and Answers

  • B
    Brian MayoAug 4, 2025
    How to prevent sample contamination in Thermo Scientific Medical Equipment?
    • M
      Melissa PetersonAug 4, 2025
      To prevent sample contamination when using Thermo Scientific Medical Equipment, apply the sample directly to the center of the resin bed, touching the tip to the resin to expel all of the sample. Avoid contact with the sides of the column. If you are using fixed-angle rotors, place the column in the same orientation each time and do not exceed the recommended centrifuge speed or time. Improper centrifugation or sample loading can lead to contamination.
  • B
    Bruce WilsonAug 11, 2025
    Why is there a low yield with my Thermo Scientific Medical Equipment?
    • M
      Morgan MelendezAug 11, 2025
      If you are experiencing low yield with your Thermo Scientific Medical Equipment, first ensure that the sample was completely in solution before adding it to the column by centrifuging the sample at 14,000 × g for 10 minutes. If a portion of the protein is still remaining in the spin column, use a stacker to recover more protein. Check for protein solubility in the final buffer or solution, as protein may have precipitated in the equilibration buffer. If the protein is bound to the resin matrix, consider using an alternative resin.
  • H
    heatherpatelAug 18, 2025
    What to do if sample doesn't flow through resin in Thermo Scientific Medical Equipment?
    • S
      Steven WilliamsAug 19, 2025
      If your sample or buffer does not flow through the resin in your Thermo Scientific Medical Equipment, make sure the centrifuge is in proper working condition. Also, ensure that the bottom closure is removed and the top cap is loosened before use.
  • S
    sarah38Aug 26, 2025
    Why is recovered protein dilute with Thermo Scientific Zeba Medical Equipment?
    • S
      Samantha MitchellAug 26, 2025
      If the recovered protein or sample is dilute when using Thermo Scientific Medical Equipment, ensure that the wash/equilibration buffer was adequately removed by centrifugation before adding the sample. The column should appear uniformly white with no solvent streaks.

Summary

Introduction to Zeba Spin Desalting Columns

Product Overview and Benefits

Details the high-performance resin for desalting/buffer exchange, exceptional recovery, and no need for chromatography systems.

Important Product Information Summary

Covers size-exclusion resin separation, sample volume optimization for desalting, and 40K MWCO alternatives.

Desalting and Buffer Exchange Procedures

Materials and General Procedure

Lists required materials like microcentrifuges and tubes, and the wash/equilibration buffer usage.

Step-by-Step Protein Desalting

Provides detailed instructions for column preparation, sample loading, centrifugation, and recovery.

Troubleshooting and Related Products

Common Troubleshooting Solutions

Addresses issues like no flow, sample contamination, low yield, and dilute samples with possible causes and solutions.

Related Thermo Scientific Products

Lists complementary products like Pierce Polyacrylamide Spin Desalting Columns.

Thermo Scientific Zeba Specifications

General IconGeneral
BrandThermo Scientific
ModelZeba
CategoryMedical Equipment
LanguageEnglish

Related product manuals