GENESYS™ 10 Series
Spectrophotometers
Operators Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the thermo spectronic GENESYS 10 and is the answer not in the manual?

thermo spectronic GENESYS 10 Specifications

General IconGeneral
TypeUV-Visible Spectrophotometer
Wavelength Range190 - 1100 nm
Detector TypeSilicon photodiode
DisplayLCD
Baseline Flatness±0.002 A
InterfaceRS-232
Power Requirements100-240V AC, 50/60 Hz
Photometric Range-0.3 to 3.0 A
Light SourceTungsten-Halogen and Deuterium lamps
Sample HolderStandard 10 mm cuvettes
Data OutputRS-232
Stray Light<0.05% T at 220 nm

Summary

Setting Up the Instrument

Instrument Setup Procedures

Steps for unpacking, placing, and connecting the instrument.

Using the Instrument

Instrument Usage: Units and SmartStart

Instrument Usage: SmartStart and Cell Correction

Running the Cell Correction Program

Performing cell correction for accurate measurements.

Instrument Usage: Measurement Procedures

Instrument Usage: Measurement Modes

Taking Measurements Automatically

Using Auto 6 or Auto 3 modes for sample measurement.

Instrument Usage: Basic Absorbance and Concentration

Basic Absorbance/%T Measurements

Performing absorbance and transmittance measurements.

Measuring a Blank

Measuring the reference sample.

Measuring Unknowns

Measuring sample absorbance or transmittance.

Basic Concentration Measurements

Measuring concentration using factors or standards.

Instrument Usage: Concentration Calibration

Measuring a Blank for Concentration

Measuring the reference sample for concentration tests.

Measuring a Standard for Concentration

Measuring a standard sample for concentration calibration.

Instrument Usage: Advanced Concentration Methods

Entering a Factor for Concentration

Inputting a factor for concentration calculations.

Measuring Unknowns for Concentration

Measuring unknown samples for concentration.

Advanced A/%T/C: Absorbance & %Transmittance

Detailed absorbance/transmittance measurements.

Instrument Usage: Advanced A/%T/C Procedures

Taking Measurements in Advanced A/%T/C

Acquiring data for Advanced A/%T/C tests.

Advanced A/%T/C: Concentration Measurements

Concentration measurements using Advanced A/%T/C.

Instrument Usage: Advanced Concentration Standards

Instrument Usage: Standard Curve Creation

Entering a Factor for Advanced A/%T/C

Inputting a factor for Advanced A/%T/C concentration.

Measuring Unknowns for Advanced A/%T/C

Measuring unknown samples for Advanced A/%T/C concentration.

Standard Curve

Measuring Standards for Standard Curves

Measuring standard samples for curve creation.

Measuring Standards Automatically

Automatic standard measurement for curve.

Measuring Standards Manually

Manual standard measurement for curve.

Standard Curve: Unknowns and Editing

Measuring Unknowns with Standard Curves

Measuring unknown samples using a standard curve.

Standard Curve Editing and Absorbance Ratio

Absorbance Ratio

Measuring Unknowns for Absorbance Ratio

Measuring unknown samples for Absorbance Ratio.

Measuring Unknowns Automatically

Automatic unknown measurement for Absorbance Ratio.

Measuring Unknowns Manually

Manual unknown measurement for Absorbance Ratio.

Kinetics

Measuring Unknowns in Kinetics

Measuring unknown samples in Kinetics mode.

Kinetics Data Analysis

Survey Scan/Scanning

Collecting a Baseline Scan

Recording a baseline scan.

Scan Data Analysis

Scanning an Unknown

Performing a scan on an unknown sample.

Scan Graph Manipulation Tools

Scan Data Calculations

Tabular Scan Data and 3-Point Net

Multiple Wavelengths

Taking Measurements

Performing multi-wavelength measurements.

Multiple Wavelengths: Manual Measurements

Taking Measurements Manually

Manual multi-wavelength measurements.

Performing Maintenance Procedures

Cleaning and Maintenance of Cells

Proper methods for cleaning cuvettes and flowcells.

Maintenance: Fuse and Lamp Replacement