Why won't my THERMOBILE IMAC 2000 S convector heater start?
- ZZachary WallNov 2, 2025
If your THERMOBILE Heating System's convector heater isn't starting, here's what to check: 1. Ensure the heater is properly connected to a power source. 2. If the burner relay indicator is on, try pressing the reset button on the operating panel. 3. Verify that the thermostat settings are correct. 4. Make sure the room thermostat isn't positioned in the hot air flow. If it is, relocate it. 5. Also, verify the air flow and then reset the convector heater. Other potential issues include a faulty burner, defective room thermostat or digital combination thermostat, a stuck fuel pump, or a defective capacitor in the burner motor, all of which would require replacement. If a room thermostat isn't being used, ensure the thermostat connection has a cap. Also check the fan thermostat settin...