EasyManua.ls Logo

Thermocold MEX VS 15 RH - User Manual

Thermocold MEX VS 15 RH
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CONTROLLER MANUAL
MEX VS 15 RH / MEX VS 16 RH
MEX VS 18 RH / MEX VS 19 RH
MEX VS 112 RH /MEX VS 112T RH
MEX VS 115 RH / MEX VS 115T RH
Cod. MCO14124H7820-04
This manual has been created for informative purpose. The company declines any responsibility for the results of any projecting or any installation based on the explanations and/or on
the technical specifications provided in this manual. It is besides forbidden the reproduction under any form of the texts and of the figures contained in this manual.
"This manual is a translation from the official italian language version. For reasons of environmental respect the Company will not provide the hard copy in the original language which
could be directly requested or downloaded from the Company website at any time. In case of any dispute, the original language manual will be the trusted one".
CONTROLLER MANUAL FOR CHILLERS
AND INVERTER AIR/WATER HEAT
PUMPS WITH AXIAL FANS

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Thermocold MEX VS 15 RH and is the answer not in the manual?

Summary

3 GENERAL SAFETY RULES

3.1 PERSONAL SAFETY EQUIPMENT

Specifies required personal protective equipment for safe operation and maintenance.

3.2 WORKERS HEALTH AND SAFETY

Outlines compliance with European directives on workplace health and safety.

5 USER - CONTROLER INTERFACE

5.1 MENU STRUCTURE DIAGRAM

Illustrates the hierarchical structure of the controller's menu system.

5.2 USER ADJUSTABLE SET POINT

Details the adjustable set points for various operating modes like summer and winter.

5.5 INPUT;OUTPUT (I;O) PORTS

Lists and describes the controller's input and output ports for system integration.

6 DYNAMIC SET-POINT ADJUSTMENT

7 SET-POINT ADJUSTMENT FROM 0-10 V INPUT

8 CIRCULATOR

8.1 OPERATION BY MEAN OF THERMOREGULATOR (Default)

Explains the default operating mode for the circulator based on thermoregulation.

8.3 OPERATION WITH ACTIVE ELECTRIC HEATER

Details circulator operation when auxiliary electric heaters are active.

8.5 PROPORTIONAL ADJUSTMENT OF THE PUMP

Describes how pump speed is adjusted proportionally to temperature differences.

9 HEAT DISSIPATION FAN MOTOR CONTROL

9.1 FAN SPEED CONTROL IN COOLING MODE

Details fan speed control logic during cooling operations.

10 CONTROL FUNCTIONS

10.1 ANTIFREEZE PROTECTION ELECTRIC HEATERS

Explains electric heater activation for antifreeze protection.

10.2 ACTIVATION OF SANITARY (DOMESTIC) HOT WATER PRODUCTION

Describes how to enable and configure domestic hot water production.

10.4 REMOTE FUNCTIONS

Explains how to control unit functions remotely via digital inputs.

10.6 AUXILIARY ELECTRIC HEATER

Covers the configuration and use of auxiliary electric heaters.

10.12 SIGNALIZATIONS OF FUNCTIONS

Describes how to signalize various unit functions and modes.

11 AVAILABLE FUNCTIONS WITH TOUCH SCREEN REMOTE CONTROL PANEL ACCESSORY

12 AVAILABLE FUNCTIONS WITH GI MODULE (optional)

12.3 MIXING VALVE MANAGEMENT

Details the PID control for mixing valve operation.

12.4 SOLAR INTEGRATION MANAGEMENT

Covers the management of solar integration functions.

14 USERS AND INSTALLERS ALLOWED CONFIGURATIONS

Thermocold MEX VS 15 RH Specifications

General IconGeneral
CategoryController
ModelMEX VS 15 RH
BrandThermocold
Input Voltage230 Vac
Frequency50/60 Hz
Protection ClassIP20
Humidity Rangenon-condensing
Weight0.2 kg

Related product manuals