EasyManua.ls Logo

Thermofilm TT-MTC2-4A - Page 2

Thermofilm TT-MTC2-4A
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27 Rosalie Street, Springvale VIC 3171
P: +61 (0)3 9562 3455 F: +61 (0)3 9548 3979
sales@thermofilm.com.au
www.thermofilm.com.au
2. Specification Data
Model Supply Max. Load Power
TT-MTC2-4A 230-240 volt AC 13 Amps (resistive) 3100 Watts
3. Operations Instructions
To set 2 hour/4 hour/6 hour mode
Press the On/Off button once and the 2 hour LED light will come on.
Press the On/Off button again and the 4 hour LED light will come on.
Press the On/Off button again and the 6 hour LED light will come on.
Press the On/Off button again and the unit will turn off.
NB: The Power LED will be lit up when the heating is on.
Temperature Control Settings
Comfort: 18°C 26°C
Backup: 5°C 15°C
NB: The above temperature parameters will be set by the Installer..
4. Installation
Installation Guidelines:
All electrical connections are to be performed by a registered electrician only, as required by
law.
Ensure that the supply is disconnected at the distribution board.
All connections are secure and tested prior to activation.
You have studied and fully understood the connection diagram.
Thermostat must be installed in the same room as the heating system.
The thermostat must be installed on an inside wall
Avoid location where there are air drafts (top of staircase, air outlets), dead air spots (behind
doors), direct sunlight or concealed chimneys.
Must be installed using a plastic (not metal) wall box (i.e. Clipsal 157/1P).