EasyManua.ls Logo

Thermoval TX - 5. PREPARING TO OPERATING; Wall Mounting Installation

Thermoval TX
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
WARNING! To avoid overheating, do not cover his radiator.
NOT ALLOWED:
● partially or completely block the ventilation holes in the radiator grilles
● place near a heater, inflammable materials and objects
● install the heater directly under the electrical socket
● operate the heater in the immediate vicinity of a bath, shower or swimming pool
● touch the plug or the surface of the heater turned on with wet hands
5. PREPARING TO OPERATING
5.1 - Remove the heater from the box. It is recommended to save the packaging for its further
use in case of dismantling the heater and long-term storage.
When storing or transporting the radiator at low temperature (if created with dew drops) before
connecting to the mains it is necessary to wait at least 2 hours at room temperature, until it
starts.
5.2 - Specify the location where the heater will be operated. You should not install a heater
within, the ventilation holes in the area of direct sunlight.
5.3 - Verify that the technical requirements for the radiator, presented in Chapter 2 of this
manual (voltage; protect the system power supply, the quality of cables and sockets, which will
be connected to the heater, are relevant for the product. If necessary, please contact dealer or
the official service representative.
5.4 - In the case of stationary installation of the heater must be noted on a wall place the
mounting holes (see Figure 1, Table 2), and attach the mounting brackets heater in every way
possible to ensure reliability of fixing the entire period of operation and provided that the
minimum distance of the radiator to the objects in the room, as shown in Figure 2, 3 (the
distance is given in centimeters).
The heater must be suspended on the upper hooks mounting brackets (for this purpose on the
rear side of the radiator, there are two rectangular holes), while the lower hooks of the handle
must touch the rear wall of the heater (do not use excessive force to avoid damage to the
housing or the cover of the radiator). Move the heater up to the entry of the lower hooks grip in
the recesses of the lower radiator grille.
Table. 2
Nominal power, kW
0,5
1,0
1,5
2,0
L, мм
177
267
377
517