12V Marine Air Conditioning
thermowell.com.au
Installation,
Operating & Maintenance
Manual

Questions and Answers

Summary

Introduction to AirJET Air Conditioners

Warnings and Precautions for Use

Unit Components and Refrigeration Circuit Description

Symbols Used in Manual

General Installation Standards

Standard Unit Installation Example

Illustrates a typical setup for the AirJET unit, detailing component placement and connections.

Positioning of AirJET Units

Provides guidelines on where to install the unit for optimal air circulation and accessibility for maintenance.

Connecting Units to Pipelines

Sea Water Circuit Installation Details

Discusses best practices for installing the sea water inlet, filter, and pump for optimal cooling.

Air Distribution Circuit

Details the use of flexible ducting for air distribution, emphasizing optimal placement of air inlets and outlets.

Condensate Drainage Circuit

Outlines the procedure for connecting the condensate drain pipework, ensuring proper slope and discharge.

Functional Schemes and Symbols

Symbols Used in Schemes

Lists and explains the graphical symbols used in the functional diagrams of the system.

AIRJET Monobloc Unit Schematic

Presents the functional diagram for the AIRJET Monobloc Unit, illustrating its sea water circuit.

Safety Devices and Protection

High Pressure Switch Function

Explains the high-pressure switch's role in monitoring condensing pressure and stopping the circuit if safety limits are exceeded.

Low Pressure Switch Function

Describes the low-pressure switch's function in monitoring evaporator pressure and stopping the circuit when pressure is too low.

Antifreeze Protection Mechanism

Details how the unit prevents evaporator water from freezing by deactivating the unit when temperatures drop too low.

Compressor Safety Features

Gas Safety Release Valve Operation

Explains the function of the compressor's gas safety release valve in managing overpressure situations.

Compressor Overheating Protection

Describes the mechanism that stops the compressor when its operating temperature exceeds 100°C.

Compressor Voltage Protection

Details the protection that stops the compressor if voltage drops below 10V or exceeds 16V.

Inspection and Maintenance Schedule

Monthly Unit Check

Recommends checking the unit's proper operation by running it for at least 10 minutes each month.

Annual Air Filter Maintenance

Outlines the annual inspection, cleaning, or replacement procedure for the unit's air filter.

Sea Water Circuit Inspection

Advises on regular inspection of the sea water circuit, especially after periods of inactivity.

Troubleshooting Common Issues

Circuit Start-up Failures

Diagnoses common causes for the circuit not starting, including safety device trips and restart timing.

Safety Device Triggering

Addresses issues related to low pressure, high pressure, and flow switch trips, providing corrective actions.

Frost Protection Triggering

Explains causes for frost protection activation, such as low water flow or temperature, and necessary actions.

Unit Shutdown After Activation

Covers scenarios where the unit shuts down shortly after activation, often due to voltage issues or safety device trips.

Electrical Installation Guidelines

Cable Sizing and Selection

Provides guidance on selecting appropriate PVC insulated cables and dimensions based on full load current.

Temperature Correction Coefficients for Flow Rate