    What to do if my Thermowell Marine Equipment unit shuts down shortly after activation?
    • A
      Alexis Simpson MDAug 5, 2025
      If your unit shuts down soon after starting, it could be due to one of the safety devices tripping. In this case, you should check the safety devices. Another possible cause is low voltage. Measure the voltage at the power supply panel and, if necessary, also in the electrical cabinet of the appliance.
  • A
    Alexa KennedyAug 9, 2025
    What to do if the water flow rate through the condenser is too low in my Thermowell AIRJET?
    • J
      jasonsanchezAug 9, 2025
      If the water flow rate through the condenser is too low, increase the water flow rate and/or check that the filter is not clogged.
  • M
    Michael LoganAug 14, 2025
    What to do if one of the safety devices has tripped in Thermowell AIRJET?
    • M
      Matthew York DDSAug 14, 2025
      If a safety device has tripped, it could be due to several reasons. Possible causes include interruptions of electrical connections (contact an authorised technician to restore the correct connection), low water flow (increase water flow rate), low temperature of the water entering the evaporator (increase incoming water temperature), a defective probe or instrument (check that the probe or measuring instrument is not defective), or a damaged compressor contactor (check the correct state of the contactor).
  • E
    erichendersonAug 25, 2025
    Why Thermowell AIRJET circuit does not start?
    • R
      Rebecca WatsonAug 25, 2025
      A circuit might not start because one of the safety devices has tripped (Low Pressure switch, High Pressure switch, Protection against phase reversal, or Antifreeze). See symptom 2 'One of the following safety devices has tripped'. Another reason could be that the timing period for preventing close restarts has not yet elapsed; the circuit can only be restarted after about 3 minutes.
  • L
    Lisa FigueroaAug 29, 2025
    What to do if contactor burnt out in Thermowell Marine Equipment?
    • R
      robinsonlouisAug 29, 2025
      If the contactor is burnt out, contact an authorised technician for replacement.
  • K
    Kayla FarleySep 10, 2025
    What to do if my Thermowell AIRJET Marine Equipment has no water flow rate?
    • C
      Claire WalkerSep 12, 2025
      If there is no water flow rate, check the sea water pump.

Summary

Introduction to AirJET Air Conditioners

Warnings and Precautions for Use

Unit Components and Refrigeration Circuit Description

Symbols Used in Manual

General Installation Standards

Standard Unit Installation Example

Illustrates a typical setup for the AirJET unit, detailing component placement and connections.

Positioning of AirJET Units

Provides guidelines on where to install the unit for optimal air circulation and accessibility for maintenance.

Connecting Units to Pipelines

Sea Water Circuit Installation Details

Discusses best practices for installing the sea water inlet, filter, and pump for optimal cooling.

Air Distribution Circuit

Details the use of flexible ducting for air distribution, emphasizing optimal placement of air inlets and outlets.

Condensate Drainage Circuit

Outlines the procedure for connecting the condensate drain pipework, ensuring proper slope and discharge.

Functional Schemes and Symbols

Symbols Used in Schemes

Lists and explains the graphical symbols used in the functional diagrams of the system.

AIRJET Monobloc Unit Schematic

Presents the functional diagram for the AIRJET Monobloc Unit, illustrating its sea water circuit.

Safety Devices and Protection

High Pressure Switch Function

Explains the high-pressure switch's role in monitoring condensing pressure and stopping the circuit if safety limits are exceeded.

Low Pressure Switch Function

Describes the low-pressure switch's function in monitoring evaporator pressure and stopping the circuit when pressure is too low.

Antifreeze Protection Mechanism

Details how the unit prevents evaporator water from freezing by deactivating the unit when temperatures drop too low.

Compressor Safety Features

Gas Safety Release Valve Operation

Explains the function of the compressor's gas safety release valve in managing overpressure situations.

Compressor Overheating Protection

Describes the mechanism that stops the compressor when its operating temperature exceeds 100°C.

Compressor Voltage Protection

Details the protection that stops the compressor if voltage drops below 10V or exceeds 16V.

Inspection and Maintenance Schedule

Monthly Unit Check

Recommends checking the unit's proper operation by running it for at least 10 minutes each month.

Annual Air Filter Maintenance

Outlines the annual inspection, cleaning, or replacement procedure for the unit's air filter.

Sea Water Circuit Inspection

Advises on regular inspection of the sea water circuit, especially after periods of inactivity.

Troubleshooting Common Issues

Circuit Start-up Failures

Diagnoses common causes for the circuit not starting, including safety device trips and restart timing.

Safety Device Triggering

Addresses issues related to low pressure, high pressure, and flow switch trips, providing corrective actions.

Frost Protection Triggering

Explains causes for frost protection activation, such as low water flow or temperature, and necessary actions.

Unit Shutdown After Activation

Covers scenarios where the unit shuts down shortly after activation, often due to voltage issues or safety device trips.

Electrical Installation Guidelines

Cable Sizing and Selection

Provides guidance on selecting appropriate PVC insulated cables and dimensions based on full load current.

Temperature Correction Coefficients for Flow Rate

Details coefficients used to adjust flow rates based on ambient air temperature for optimal performance.

Regulatory and Standards References

Company Address and Contact Information

Thermowell AIRJET Specifications

General IconGeneral
BrandThermowell
ModelAIRJET
CategoryMarine Equipment
LanguageEnglish

Related product manuals