Do you have a question about the Thies CLIMA 5.4103.1 Series and is the answer not in the manual?
| Accuracy Temperature | ±0.2 °C (at 20 °C) |
|---|---|
| Resolution Temperature | 0.1 °C |
| Resolution rel. humidity | 0.1 % RH |
| Rainfall Measurement | Yes |
| Protection class | IP66 |
| Measurement Parameters | Temperature, relative humidity, air pressure, wind speed, wind direction, precipitation, solar radiation |
| Measuring principle | Various (e.g., Pt100 for temperature, capacitive for humidity, ultrasonic for wind) |
| Temperature Range | -40 to +70 °C |
| Humidity Range | 0 to 100 % RH |
| Accuracy rel. humidity | ±2 % RH |
| Wind Speed Range | 0 to 60 m/s |
| Wind Direction Range | 0° to 360° |
| Precipitation Type | Rain, Snow |
| Solar Radiation Range | 0 to 2000 W/m² |
| Power Supply | 12 VDC to 30 VDC |
| Output | RS485, SDI-12 |
| Operating temperature | -40 to +70 °C |
| Housing material | plastic parts UV-resistant |
| Output signal | RS485, SDI-12 |