EasyManua.ls Logo

Thorn SENSA MRE SEND DSI User Manual

Default Icon
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
W4047H
Installation and Commissioning
Instructions
Note: SENSA SENP required for commissioning
At the end of their useful life
the packaging and product
should be disposed of via a
suitable recycling centre.
Do not dispose of with normal
household waste.
Do not burn.
Electrical Connections
115mm
65mm
Supply
230V
50Hz
Push-to-Make
Mains-Rated
Retractive Switch
Brown
Blue
Orange
White
DSI out (96211279)
DALI out (96238877)
Polarity-free; do not connect to other detectors.
Red
L
N
Sensa Digital Detector,
ceiling mounted
SENSA MRE SEND DSI (96211279)
SENSA MRE SEND DALI (96238877)
Thorn Lighting Limited
www.thornlighting.com
T
Input
(see overleaf)
Technical Data
RECOMMENDED MAXIMUM MOUNTING HEIGHT: 3.0m
RANGE: Cone-shaped detection pattern, diameter (at floor level) = 2.4 x mounting height
OPERATING VOLTAGE: 230V 50Hz
PRODUCT RATING & RECOMMENDED CIRCUIT PROTECTION: 10 Amps
CAPACITY: 8 ballasts
OUTPUT: 2-wire digital polarity free-max extended cable length: 12m
PHOTOCELL: Regulating
OFF DELAY: 5-35 minutes
DEPTH REQUIRED BEHIND CEILING: 125mm
WEIGHT: 70g approx excluding cable
COLOUR: White
MATERIAL: Flame retardant PC/ABS
IP RATING: IP 40
6.0m
2.5m
Question and Answer IconNeed help?

Do you have a question about the Thorn SENSA MRE SEND DSI and is the answer not in the manual?

Thorn SENSA MRE SEND DSI Specifications

General IconGeneral
BrandThorn
ModelSENSA MRE SEND DSI
CategorySecurity Sensors
LanguageEnglish